Assembly / Owner’s Manual
55
Condition/Problem 7KLQJVWR&KHFN Solution
1RGLVSOD\XQLWZLOOQRWWXUQRQ Console in sleep mode 7RXFKGLVSOD\WRZDNHXS&RQVROH
Power Switch 0DNHVXUHWKDWWKH3RZHU6ZLWFKLVÀLSSHGWRRQ
Power Cord &KHFNIRUYLVXDOVLJQWKDW3RZHU&RUGLVGDPDJHG5HSODFH3RZHU&RUGLI
damaged.
&KHFNHOHFWULFDOZDOORXWOHW 0DNHVXUHXQLWLVSOXJJHGLQWRDIXQFWLRQLQJZDOORXWOHW
&KHFNFRQQHFWLRQDWIURQWRIXQLW Connection should be secure and undamaged. Unplug connector and
LQVSHFWLQOHWIRUDQ\GDPDJH3OXJFRQQHFWRUEDFNLQWRLQOHW
&KHFN6WDWXV/(' ,I6WDWXV/('EOLQNLQJTXLFNO\WKHQ&RQVROHLVH[SHULHQFLQJDQHUURU'LVFRQ-
nect power to machine for 30 seconds, and then reconnect it.
&KHFNGDWDFDEOH
FRQQHFWLRQVRULHQWDWLRQ
%HVXUHFDEOHLVFRQQHFWHGVHFXUHO\DQGRULHQWHGSURSHUO\6PDOOODWFKRQ
connector should line up and snap into place.
&KHFNGDWDFDEOHLQWHJULW\ $OOZLUHVLQFDEOHVKRXOGEHLQWDFW,IDQ\DUHYLVLEO\FULPSHGRUFXWUHSODFH
cable.
&KHFNFRQVROHGLVSOD\IRU
damage
&KHFNIRUYLVXDOVLJQWKDWFRQVROHGLVSOD\LVFUDFNHGRURWKHUZLVHGDPDJHG
Replace Console if damaged.
If the above steps do not resolve the problem, contact Customer Service (if
LQVLGH86&DQDGDRU\RXUORFDOGLVWULEXWRULIRXWVLGH86&DQDGD
Speed or Incline does not
DGMXVWPDFKLQHWXUQVRQDQG
operates)
&KHFNGDWDFDEOHLQWHJULW\IURP
&RQVROH%XWWRQ$VVHPEO\WR
Console
$OOZLUHVLQFDEOHVKRXOGEHLQWDFW,IDQ\DUHYLVLEO\FULPSHGRUFXWUHSODFH
cable.
&KHFNGDWDFDEOH
FRQQHFWLRQVRULHQWDWLRQ
%HVXUHFDEOHLVFRQQHFWHGVHFXUHO\DQGRULHQWHGSURSHUO\6PDOOODWFKRQ
connector should line up and snap into place.
&KHFN&RQVROHGLVSOD\IRU
damage
&KHFNIRUYLVXDOVLJQWKDWFRQVROHGLVSOD\LVFUDFNHGRURWKHUZLVHGDPDJHG
Replace Console if damaged.
If the above steps do not resolve the problem, contact Customer Service (if
LQVLGH86&DQDGDRU\RXUORFDOGLVWULEXWRULIRXWVLGH86&DQDGD
8QLWRSHUDWHVEXW%OXHWRRWK
®
Heart Rate (HR) not displayed
%OXHWRRWK
®
HR device )XOO\FKDUJH+5GHYLFHDQGDFWLYDWH%HVXUHDQ\SURWHFWLYHFRYHUKDVEHHQ
UHPRYHGIURP+5VHQVRUV0DNHVXUHVHQVRUVDUHGLUHFWO\DJDLQVWVNLQDQG
contact area is wet.
Heart Rate 6WUDS%DWWHULHV If HR device has replaceable batteries, install new batteries (the provided
heart rate armband does not have replacement batteries).
Interference 7U\PRYLQJXQLWDZD\IURPVRXUFHVRILQWHUIHUHQFH790LFURZDYHHWF
2Q2II/('EXWWRQRQ+5
device
'XULQJDZRUNRXWRQO\SXVKWKH2Q2II/('EXWWRQRQFHWRDFWLYDWHWKH
armband.
Replace HR device If interference is eliminated and HR does not function, replace HR device.
If the above steps do not resolve the problem, contact Customer Service (if
LQVLGH86&DQDGDRU\RXUORFDOGLVWULEXWRULIRXWVLGH86&DQDGD
Speed display is not accurate Display set to wrong unit of
PHDVXUH(QJOLVK0HWULF
Change display to show correct units.
Fan will not turn on or will not
turn off
Reset machine Unplug unit from electrical outlet for 5 minutes. Reconnect to outlet.
Fan will not turn on, but Console
operates
&KHFNIRUEORFNDJHRIIDQ Unplug unit from electrical outlet for 5 minutes. Remove material from fan. If
necessary, detach the Console to help with removal. Replace the Console if
XQDEOHWRUHPRYHEORFNDJH
8QLWURFNVGRHVQRWVLWOHYHO &KHFNOHYHOHUDGMXVWPHQW $GMXVWOHYHOHUVXQWLOPDFKLQHLVOHYHO
&KHFNVXUIDFHXQGHUXQLW $GMXVWPHQWPD\QRWEHDEOHWRFRPSHQVDWHIRUH[WUHPHO\XQHYHQVXUIDFHV
Move machine to level area.
7KXPSLQJVRXQGZKHQEHOW
operates
:DONLQJEHOW :DONLQJEHOWQHHGVWREHXVHGIRUZHDULQSHULRG6RXQGZLOOJRDZD\DIWHU
the wear in period.
Troubleshooting