Installer Guide 4
Wiring Terminations for model 5320
Terminal Function Description
A Output EconomizerControl
G Output FanControl
Rc Input 24VoltACCoolingTransformer
(DualTransformerSystemsOnly)
Rh Input PowerConnection(24VoltACHeating
TransformerorMillivoltPowerSource)
W1/E/ Output (W1)1stStageConventionalHeat,
AUX1 (E)EmergencyHeat,
(AUX1)1stStageAuxiliaryHeat
W2/AUX2 Output (W2)2ndStageConventionalHeat,
(AUX2)2ndStageAuxHeat
W3/O/B Output (W3)3rdStageConventionalHeat,
(O)CoolActiveReversingValve
(B)HeatActiveReversingValve
Y1 Output 1stStageCompressor
Y2 Output 2ndStageCompressor
C Input 24VoltACTransformerCommon
L Input SystemMalfunctionIndicator
S1
S2
Connecting Your Wires (continued)
3
Input OptionalRemoteSensor(indoororoutdoor)