Troubleshooting
7-6
Digital Compact
When touching the
equipment you experi-
ence a slight electric
shock.
DANGER!
If none of the reme-
dial actions described
is successful, imme-
diately de-energise
the equipment!
Inspect connecting socket and power
supply cable for damage.
Inspect mains connection.
In this case, replace the power supply
module and send the defective one to
BRANSON Ultrasonics.
The temperature of
horn, booster and
Converter exceeds
40°C.
Occasional occur-
rence of overload con-
ditions.
Check for fretting corrosion on the
mating surfaces of the acoustic stack.
Fretting corrosion results in a black,
crusty build-up resulting from friction
between metal parts.
Remove this deposit (please refer to
chapter 7.2.5).
Tab. 7-5 Troubleshooting: Weld cycle
Fault Cause and Remedy
STOP