Series 6A Installation, Operation & Maintenance – Field Connections
6A O & M : 7
II. Hazardous Area (Intrinsically Safe)
A. Two Wire
6
7
8
9
10
#
4 to 20 mA
Positioner
Binary input 1
Intrinsically safe
power source
Non-hazardous area
Hazardous area, Zone 1
EEx
B. and C. Two Wire Connection When Using a 2/3/4 Wire
Device and HART
6
7
8
9
2
3
4
5
10
4 to 20 mA
Positioner
Binary input 1
E
A
Intrinsically safe
power source
Non-Hazardous
area
Hazardous area, Zone 1
EEx
HART Communicator
6A-6DR52**-*E*** only
+
I
#
D. Three/Four Wire
6
7
8
9
2
3
4
5
10
18 to 30 V
Positioner
Binary input 1
E
A
Intrinsically safe
power source
Non-hazardous area Hazardous area, Zone 1
EEx
EEx
HART Communicator
6A-6DR52**-*E*** only
4 to 20 mA
+
I
+
I
*)
*)
*) Three-wire connection only
#
E. Profibus DA/DP, Foundation Fieldbus
4 ... 20 mA
BE1 = Binary Input
7
8
9
10
+
J
6
Input for safety shutdown (activated using coding jumper)
1)
30 V
24 V
+
BE1 = Binary Input
7
9
10
+
6
1)
81
82
Input for safety shutdown (activated using coding jumper)
1)
≤ 24 V
BE1 = Binary Input
7
9
10
+
6
81
82
HART
modem
PC/Laptop
R 250 W if req.
1)
3
Only required with current sources not conforming to HART1)
2
3
4
5
+
I
l
y
= 4 ... 20 mA
6
7
8
l
W-
l
H+
1) Jumper between 5 and 7 only for three-wire system
2
3
4
5
+
J
6
7
8
9
10
4 ... 20 mA
0/4 ... 20 mA
2
3
4
5
+
6
7
8
9
10
18 ... 30 V
J
+
BE1 = Binary Input
BE1 = Binary Input
1)
Power Supply
Non-Hazardous Hazardous area, Zone 1
Multiple Positioners Field Wiring
Split Range
6
7
8
9
2
3
4
5
10
6
7
8
9
2
3
4
5
10
+ 18 to 30 V
+ 0/4 to 20 mA
BE1
Entire positioning
range I
y
Auxiliary power
EEx
L+
V
EEx
I
y
I
Positioning range 1
BE1
Positioning range 1
M
M
#
#
Non-hazardous area Hazardous area, Zone 1
Intrinsically safe power sources
Series connection of 2 positioners, e.g. split range (auxiliary power wired separately), EEx i

Other manuals for Bray 6A series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bray 6A series and is the answer not in the manual?

Bray 6A series Specifications

General IconGeneral
BrandBray
Model6A series
CategoryValve Positioners
LanguageEnglish

Related product manuals