EasyManua.ls Logo

Brecknell HS300 - Page 19

Brecknell HS300
68 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
15
0.2 lb
0.1 kg
0.2 lb
5 oz
2 lb
1 kg
2 lb
Not available
20 lb
10 kg
20 lb
Not available
0.0005 lb 0.0002 kg 0.0005 lb Not available
0.005 lb
0.002 kg
0.005 lb
0.1 oz
0.05 lb 0.02 kg 0.05 lb 1 oz
0.5 lb
0.2 kg
0.5 lb
Not available
5 lb 2 kg 5 lb Not available
50 lb
20 kg
50 lb
Not available
5.11) P11.x: select the weighing unit that may be chosen by pressing UNIT
x = 0 : only kg
x = 1 : only lb
x = 2 : only lb: oz
x = 3 : kg or lb
x = 4 : kg or lb: oz
x = 5 : lb or lb: oz
x = 6 : kg, lb, or lb: oz
Above setting of units may not be available as per above tables in 5.10
5.12) P12.x: Power-on zero-point range
x = 0 : calibration zero point (CAL.P0) +1%FS
x = 1 : calibration zero point (CAL.P0) +2%FS
x = 2 : calibration zero point (CAL.P0) +5%FS
x = 3 : calibration zero point (CAL.P0) +10%FS
x = 4 : calibration zero point (CAL.P0) +20%FS
x = 5 : calibration zero point (CAL.P0) +50%FS
x = 6 : calibration zero point (CAL.P0) +100%FS
x = 7 : No limitation
5.13) P13.x: Zero range for ZERO button after switch on
x = 0 : Power-on zero-point ±1%FS;
x = 1 : Power-on zero-point ±2FS;
x = 2 : Power-on zero-point ±3%FS;
x = 3 : Power-on zero-point ±4%FS;
x = 4 : Power-on zero-point ±5%FS;

Related product manuals