13
Problem Cause Soluon
The dispenser
does not dispense
coee (Connued)
If the dispenser was used
without a lter adapter (19)in the
intake line (11), coee parcles
can get into the pump and
damage or block valve parts. This
could lead to a lack of sucon
and may void the warranty.
In such a situaon, the dispenser
and the pump must be ushed
with tap water.
1) Screw o the tap jet-nozzle
spout (3).
2) Connect the intake line (11)
to a water tap that provides
water with 2-4 bar.
3) Put the air-compressor
switch (16) in the
“I” (on) posion
4) Turn on the water supply.
5) Open the dispenser tap
(without the jet-nozzle
spout) and ush it with the
pressurized water from the
tap.
6) Open and close the
dispenser tap (1 and 2) in
intervals to ush out all
parcles from the pump.