EasyManuals Logo

Briggs & Stratton Portable Generator User Manual

Briggs & Stratton Portable Generator
64 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #27 background imageLoading...
Page #27 background image
27
Troubleshooting
Problem Cause Correction
Engine is running, but no AC
output is available.
1. One of the circuit breakers is open.
2. Fault in generator.
3. Poor connection or defective cord set.
4. Connected device is bad.
1. Reset circuit breaker.
2. Contact authorized service facility.
3. Check and repair.
4. Connect another device that is in good
condition.
Engine runs well at no-load but
"bogs down" when loads are
connected.
1. Short circuit in a connected load.
2. Engine speed is too slow.
3. Generator is overloaded.
4. Shorted generator circuit.
1. Disconnect shorted electrical load.
2. Contact authorized service facility.
3. See Don't Overload Generator.
4. Contact authorized service facility.
Engine will not start; starts and
runs rough or shuts down when
running.
1. Engine switch set to off position (O).
2. Fuel valve is in "Off" position.
3. Low oil level.
4. Dirty air cleaner.
5. Out of fuel.
6. Stale fuel.
7. Spark plug wire not connected to spark
plug.
8. Bad spark plug.
9. Water in fuel.
10. Flooded.
11. Excessively rich fuel mixture.
12. Intake valve stuck open or closed.
13. Engine has lost compression.
1. Set switch to on position (I).
2. Turn fuel valve to "On" position.
3. Fill crankcase to proper level or place
generator on level surface.
4. Clean or replace air cleaner.
5. Fill fuel tank.
6. Drain fuel tank and carburetor; fill with
fresh fuel.
7. Connect wire to spark plug.
8. Replace spark plug.
9. Drain fuel tank and carburetor; fill with
fresh fuel.
10. Wait 5 minutes and re-crank engine.
11. Contact authorized service facility.
12. Contact authorized service facility.
13. Contact authorized service facility.
Engine lacks power.
1. Load is too high.
2. Dirty air filter.
1. See Don't Overload Generator.
2. Replace air filter.
Engine "hunts" or falters. Carburetor is running too rich or too lean. Contact authorized service facility.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Briggs & Stratton Portable Generator and is the answer not in the manual?

Briggs & Stratton Portable Generator Specifications

General IconGeneral
BrandBriggs & Stratton
ModelPortable Generator
CategoryPortable Generator
LanguageEnglish

Related product manuals