ASSAULT:
TYPE
6.
The
Assault
Loop
is
a
24
hour
loop
which
sounds
the
same
as
a
burglary
alarm.
It
Will
trip
a
continuous
siren
for
a
1
-
15
minute
period
(as
programmed).
The
assault
alarm
is
cleared
by
entering
a
valid
disarm
code.
The
Assault
Loop
is
used
to
summon
the
police.
SILENT
ASSAULT:
TYPE
7.
Silent
Assault
is
the
same
as
assault
except
that
the
alarm
does
not
sound.
AUXILIARY:
TYPE
8.
The
Auxiliary
Loop
is
a
24
hour
loop
which
sends
a
report
to
the
AMC
when
it
is
Violated.
It
will
not
sound
an
alarm
The
Auxiliary
Loop
can
be
used
to
monitor
critical
conditions
such
as
temperatures
of
freezers
or
pipes,
to
report
water
leaks,
or
as
a
silent
tamper
or
holdup
loop.
DURESS:
TYPE
9.
The
Duress
Loop
is
a
24
hour
loop
which
will
report
to
the
AMC
without
indicating
gn
alarm
on
the
keypad
display.
No
alarm
will
sound.
NOMAD
DELAY:
TYPE
10.
Operates
like
the
normal
NOMAD
zone
but
if
the
zone
is
violated
while
the
system
is
armed
and
during
other
than
an
Exit
or
Entry
time,
a
fixed
entry
delay
of
20
seconds
will
initiate.
FIRE:
TYPE
11.
The
Fire
Loop
is
a
24
hour
loop
which
will
trip
a
fire
alarm
if
it
is
violated
by
closing.
The
fire
alarm
will
sound
a
pulsed
siren.
The
fire
sound
has
priority
over
the
burglary
or
assault
sound.
The
alarm
time
is
1
-
15
mjnutes
or
not
timed
out
(as
programmed).
The
siren
wiil
pulse
2
seconds
on/off.
If
the
Fire
Loop
is
violated
by
opening,
a
trouble
will
result.
The
fire
alarm
can
be
silenced
by
entering
a
yalid
disarm
code.
This
loop
is
used
for
smoke
detectors
and
other
fire
sensors.
The
Fire
power
is
only
reset
when
the
unit
is
turned
off
after
a
Fire
Alarm
zone
has
been
violated-
If
the
zone
is
still
violated
(shorted),
the
ACP
will
automatically
reset
the
fire
power
30
minutes
later.
If
the
second
attempt
fails,
the
"Call
Brinks"
segment
on
the
keypad
is
lit
ancf
the
trouble
heep
initiated.
The
panel
will
then
report
a
trouble
to
the
central
station.
LOCAL:
TYPE
12.
The
Local
Loop
is
a
24
hour
loop
which
will
sound
the
siren
for
approximately
one
second
whenever
the
loop
is
violated
by
opening.
The
ACP
will
not
report.
This
loop
can
be
used
to
guard
a
pool
or
other
areas,
such
as
gun
cabinets,
dangerous
to
children.
This
loop
can
be
used
to
announce
trouble
on
an
RF
system
or
to
guard
areas
such
as
liquor
cabinets
from
children,
servants,
or
relatives.
NOT
AVAILABLE:
TYPE
13.
NON
EXISTENT:
TYPE
14
Assignment
of
this
zone
type
will
cause
any
activity
on
the
zone
to
be
ignored.
NOT
AVAILABLE:
TYPE
15.