Service Manual 32 – Contour 3 Series, Profiler & Advance – Approved Issue 5 Printed 2/13/2014 11:50:17 AM
43
Cooler Operation:
(cont.)
Networker Control in Manual Mode
When operating the Cooler in manual mode, the Networker screen changes to
display a pump and fan button for manual selection.
The rotary dial is used to select the constant fan speed.
The Pre-wet times apply to manual mode, in the same way described for Auto mode.
However in manual mode, the Pre-wet period can be extended by simply operating
the pump longer without the fan.
Fan only operation is available for air movement in high humidity climate conditions,
or for ventilation and air circulation.
NOTE: Should the pump be turned ON whilst the fan is operating, then the fan will be
forced OFF for the Pre-wet period, then come back ON again automatically.