Trident Water Management System
The Contour Cooler's tank water level is regulated, by turning ON and OFF the water
inlet solenoid as required, according to the operating conditions.
After the initial filling, at which point the water inlet solenoid turns OFF, the Cooler
looses tank water volume due to evaporation, in the normal course of the unit's
operation.
The rate of water evaporation is dependant on the current climatic conditions, the
Cooler's operating fan speed and the condition of the filter pad material. All of these
of course are infinitely variable.
The water management system uses 3 stainless steel probes, to detect the water
level within the tank. The mid level probe is the common low voltage output. The
shortest probe is the high water level. The longest probe is the low water level.
The switch function of both version are the same, however, the revised version
design has the common voltage output probe, at a closer position to both low and
high level probes.