Service Manual 32 – Contour 3 Series, Profiler & Advance – Approved Issue 5 Printed 2/13/2014 11:50:17 AM
47
Cooler Operation:
(cont.)
Aquasave Operation:
(Contours Only).
The Aquasave water treatment module was designed to reduce the requirement for
flushing, thus saving water. The module introduces oxidants into to the trough water
through a diffuser ball. These oxidants then prevent the growth of bacteria and micro-
organisms in the water.
The Aquasave module will only operate when the pump is operating, and has an
internal timer that will cycle the Aquasave on and off. The timer is set to cycle the unit
7 minutes on and 7 minutes off.
The module has an internal air pump which draws the air though a filter located under
the front of the cooler trough. This air then passes through a high intensity spark
where the air is filled with oxidants. There air then passes through a tube to the
diffuser ball which should be submerged beneath the water.