Service Manual 32 – Contour 3 Series, Profiler & Advance – Approved Issue 5 Printed 2/13/2014 11:50:17 AM
45
Cooler Operation
(cont.)
Wash Service
(cont.)
Networker ON - No
call for Operation
Call for Fan
Operation
Call for Pump
Operation with
or without Fan
ServoSeal
opens
Delay = 20
seconds
(ServoTime)
Fan turns ON
ServoSeal
opens
Delay = 15
seconds
(ServoTime)
Inlet Valve
opens and
Tank fills
Water at low
level
Pump turns
ON
Pre-Wet time
starts
Pre-Wet
complete
Fan turns ON
if required
Networker turned
OFF or call for
pump and fan to
OFF
Delay = 60 minutes
(ServoCloseDelay)
ServoSeal
Closes 15
seconds
Delay = 45
seconds
(WashWaitTime)
Water Inlet Valve
opens 30 seconds
(WashTime)
Delay = 45
seconds