242 Fabric OS Command Reference
53-1001764-02
fanEnable
2
fanEnable
Enables a fan unit.
Synopsis fanenable unit
Description Use this command to set a previously disabled fan unit back to the default RPM speed.
Notes This command is not available on nonbladed systems except for the Brocade 4100, 4900, and
5300.
The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may
be in place. Refer to chapter 1, "Using Fabric OS commands" and Appendix A, "Command
Availability" for details.
Operands This command has the following operand:
unit Specify the fan unit number to enable.
Examples To enable a fan unit:
switch:admin> fanenable 1
Fan unit 1 has been enabled
See Also fanDisable, fanShow