Fabric OS Command Reference 253
53-1001764-02
fcipPathTest
2
5 Central ASIC FC loopback
7 SFP and central ASIC FC loopback
8 PHY and central ASIC FC loopback
9 FCIP FPGA GMAC and central ASIC FC loopback
-nframes count Specifies the number of frames to send. The test progresses until the
specified number of frames are transmitted on each port. The default value is
100 (Brocade 7500/FR4-18i and Brocade 7800/FX8-24).
-length data_length
Specifies the data length of the frames used in the test (Brocade
7500/FR4-18i only). The default is 1,024; the maximum is 2,112 FC frames
and 8,196 data packets.
-compress mode Specifies the compression device for which to select or to bypass data
compression for the test (Brocade 7500/FR4-18i only). By default, data
compression is used. This setting is applicable only to path mode 1 and 2.
Examples To run the test on slot 2 with PHY loopback sending 10 frames:
switch:admin> fcippathtest --slot 2 -path 2 -nframes 10
Running fcippathtest ..............
Test Complete: fcippathtest Pass 10 of 10
Duration 0 hr, 1 min & 50 sec (0:1:50:942).
passed.
Diagnostics When it detects failures, the test may report one or more of the following error messages:
PATH_TEST_ERR
PATH_TEST_CHIP_INIT_ERR
PATH_TEST_IMAGE_ERR
PATH_TEST_TIMEOUT_ERR
PATH_TEST_HEARTBEAT_ERR
PATH_TEST_INVALID_RESULT
PATH_TEST_GE_PORT_ENABLE_ERR
PATH_TEST_GE_PORT_DISABLE_ERR
See Also fcipChipTest