APPENDIX D REFERENCE LIST OF MX-2000/4000/5000/7000 SERIES UNIQUE COMMANDS - 6
3.1.2.  PJL mailbox protection & bin number setting 
Format 
@PJL SET/DEFAULT MAILBOXPROTECT=TrayNumber 
Parameter 
TrayNumber 
<HL-2060/2460/7050> 
  Lower unit:    #1 to 5 from bottom to top 
  Lower unit + Upper unit:  #1 to 10 from bottom to top 
<HL-3260> 
#1 to 4 from bottom to top 
Default = 0 
<HL-L6300/L6400> 
HL-L6300/L6400 series do not support this command. 
Explanation 
  This command sets the bins with numbers larger than the TrayNumber specified as mailbox use only.  They 
cannot then be used for either stacker or sorter functions. 
  If the bin number is set to 0, the mailbox protection is released, then all bins can be used for stacker and 
sorter functions. 
  If the bin number is set out of the effective range, this command is ignored. 
<HL-2060/2460/7050> 
Setting type  Effective range
  MX not installed  0 
  Lower unit installed 
0, 1  5 
  Lower & upper unit installed 
0, 1  10 
<HL-3260> 
Setting type  Effective range
  MX not installed  0 
  MX installed 
0, 1  4 
  The difference between the SET and DEFAULT selection and the effective period of this setting follow the 
PJL specifications. 
 
3.1.3.  PJL avoidance of mailbox bin full 
Command 
@PJL SET/DEFAULT AVOIDMAILBOXFULL=ON/OFF 
Parameter 
ON/OFF 
  OFF:  Paper is ejected to the printer face-down output tray when the specified tray is full. 
  ON:  Paper is not ejected to the printer face-down output tray even when the specified tray is full. 
Default = OFF 
Explanation 
  When paper is ejected into a bin specified by a setting command which limits the bin selection, this 
command selects whether to eject automatically paper to the printer face-down output tray or not when the 
specified bin is full. 
  The difference between the SET and DEFAULT selection and the effective period of this setting follow the 
PJL specifications.