CHAPTER 8 BAR CODE CONTROL - 10 
  When Code 128 Set A, Set B, or Set C is selected with the parameter "t12" or "12," "t13" or "T13," or "t14" 
or "T14" respectively:     
  Code sets A, B and C are individually selectable.    Set A encodes characters in the range Hex 00 to 5F.    Set 
B encodes characters in the range Hex 20 to 7F.    Set C encodes numeric pairs in the range 00 to 99.     
-  Switching is allowed between the code sets by sending %A, %B, or %C.     
-  FNC 1, 2, 3, and 4 are produced with %1, %2, %3, and %4.     
-  The SHIFT code, %S, allows temporary switching (for 1 character only) between    set A and set B and 
vice versa.   
-  To print the  "%" character,    it must be sent twice. 
When you put "?" on the end of the data, a check digit is automatically added. 
  When ISBN (EAN) is selected with the parameter "t130" or "T130":     
  The rules are the same as for    "t5" or "T5" 
  When the ISBN (UPC-E) is selected with the parameter "t131" or "T131":     
The rules are the same as for "t6" or "T6" 
  When EAN 128 set A, set B or set C is selected with the parameter "t132" or "T132," "t133" or "T133" or 
"t134" or "T134" respectively: Same rules apply as for "t12" or "T12," "t13" or "T13", or "t14" or "T14." 
 
3.13.  Box Drawing 
(except HL-
L5000D/L5580D/L5100DN/L5200DW/L6200DW/L6300DW/L6400DW/L8250CDN/L8350CDW/L9200CDW
/L9300CDW) 
ESC i ... E (or e) 
  "E" or "e" is a terminator.     
 
3.14.  Line Block Drawing 
(except HL-
L5000D/L5580D/L5100DN/L5200DW/L6200DW/L6300DW/L6400DW/L8250CDN/L8350CDW/L9200CDW
/L9300CDW) 
ESC i ... V (or v) 
  "V" or "v" is a terminator.     
 
3.15.  Expanded Character Data Start 
(except HL-
L5000D/L5580D/L5100DN/L5200DW/L6200DW/L6300DW/L6400DW/L8250CDN/L8350CDW/L9200CDW
/L9300CDW) 
n = "l" or "L"   
Data that follows "l" or "L" is read in as expanded character data (or labeling data).    Expanded character data 
must end with the " \ " code (5CH), which also terminates this command.    To print the '\' character, you must 
input '\\'.