EasyManua.ls Logo

Brune HP50 - Electrical Connections; Operating Conditions; Specifications

Brune HP50
32 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
21 [EN]
Connect the dehumidifier and set the desired humidity.
10. ELECTRICAL CONNECTIONS
This dehumidifier was designed to operate in a 220-240 V~50Hz electrical installation. Make sure that the electric sockets
are connected to earth and that all safety precautions are taken.
11. OPERATING CONDITIONS
This dehumidifier can be operated within an ambient temperature range from +5 to +32°C and with a relative humidity
from 35% to 90%. It is suitable for application in residential buildings, offices, museums, archives, garages and storage
rooms.
12. SPECIFICATIONS
Model
HP 50
Temperature Range
+5 °C - +32°C
Relative Humidity Range
35% - 90%
Nominal Airflow
(m³/h)
n = 1700 rpm
1065
n = 1200 rpm
885
Defrosting System
Hot gas bypass
Rated Voltage
220-240 V~50 Hz
Power Consumption
32°C 80%
1220 W
Refrigerant
0,650 kg R454C
GWP
154
ODP
0
This is a hermetic cooling circuit filled with a mildly flammable
fluorinated refrigerant
Drying Capacity (l/24h)
27°C 80%
45
32°C 60%
50
Dehumidifier Dimensions
W×D×H [mm]
455 x 540 x 770
Weight
48 kg
Electronic Control
Operating Hours Counter