EasyManuals Logo

Bryant 352AAV User Manual

Bryant 352AAV
62 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #6 background imageLoading...
Page #6 background image
6
A05070
17
5
16
"
24
1
2
"
27
9
16
"
TYP
27
5
8
"
29
1
1
16
"
TY
P
30
13
16
"
32
5
8
"
TYP
33
1
4
"
TY
P
CONDENSA
TE
DRAIN
TRA
P
LOCA
TION
(ALTERN
AT E
UPFLOW)
7
8
-IN
.
DI
A
ACCESSOR
Y
POWER ENTRY
7
8
-IN. DIA
POWER CONN
CONDENS
ATE DRAIN
TRAP LOCA
TION
(DOWNFLOW &
HORIZONTAL LEFT)
26
15
16
"
24
1
2
"
22
5
16
"
2
-IN. COMBUSTION-
AIR CONN
1
2
-IN. DIA
GAS CONN
2
-IN.
VEN
T
CONN
1
2
-IN. DI
A
THERMOSTAT
ENTRY
22
11
16
"
SIDE INLET
23
1
4
" TY
P
SIDE INLET
1
1
4
"
1"
E
INLET
11
16
"
1
1
16
"
D
13
16
"
13
16
"
OUTLET
A
AIRFLOW
OUTLET
26
15
16
"
28
1
2
"
22
5
16
"
19
"
13
16
"
5
8
"
5
16
"
1
"
39
7
8
"
22
1
4
"
TYP
11
16
"
7
16
"
24
3
16
"
BOTTOM INLET
18
1
4
"
22
11
16
"
CONDENSATE DRAIN
TRA
P LOCATION
(DOWNFLO
W &
HORIZONTAL RIGHT)
OR A
L
TERNATE
1
2
-IN. DI
A GAS CONN
2-IN.
COM
BUSTION-
AIR CONN
1
2
-IN. DIA
GAS CONN
7
8
-IN. DIA
POWER CONN
1
2
-IN. DIA
THERMOS
TAT EN
T
R
Y
2-IN
.
VENT CONN
DIMPLE LOCATORS
FOR HORIZONTA
L
HANGING
14
1
2
"
TYP
SIDE INLE
T
N
O
TES: 1.
Minimum retu
rn-air openings at furnace, based on metal duct. If flex duct is used,
see flex duct manuf
acturer‘s recommendation for equivalent diameters.
2. Minimum return-air opening at furnace:
a. For 800 CFM 16-in . (406mm)
round or 14
1
/
2
(368mm)
x 12-in
. (305mm) rectangle.
b. For 1200 CFM 20-in . (508mm)
round or 14
1
/
2
(368mm)
x 19
1
/
2
-in. (495mm) rectangle
.
c. For 1600 CFM 22-in .(559mm)
round or 14
1
/
2
(368mm) x 23
1
/
4
-in.(591mm) rectangle
.
d.
For airfl
ow requirements above 1800 CFM, see Air Deliver
y table in Product Data
lite
rature for specific use of single side inlets. The use of both side inlets, a
combination of 1 side and the bottom, or the bottom only will ensure adequate
return air openings f
or airfl
o
w requirements ab
o
v
e 1800 CFM at 0.5 W.C. ESP.
9
7
16
"
TYP
26
15
16
" TYP
CONDENS
A
TE
DRAIN LOCA
TION
(UPFL
OW)
30
1
2
"
9
16
"
TYP
CONDENSA
TE
DRAIN LOCATION
(UPFL
O
W)
26
1
4
"
26
1
4
"
(684mm)
(667mm)
(666mm)
(567mm)
(51mm)
(51mm)
(13mm)
(13mm)
(576mm)
(368mm)
(32mm)
(25mm)
(591mm)
(684mm)
(240mm)
(440mm)
(622mm)
(700mm)
(702mm)
(754mm)
(783mm)
(829mm)
(845mm)
(22mm)
(22mm)
(21mm) (21mm)
(17mm)
(17mm)
(464mm)
(775mm)
(565mm)
(614mm)
(25mm)
(
1
1mm)
(17mm)
(1013mm)
(8mm)
(16mm)
(21mm)
(14mm)
(483mm)
(567mm)
(667mm)
(694mm)
(724mm)
Dimensions --- IN. (mm)
UNIT SIZE
A D E
060--- 12 / 036060 17-1/2 (445) 15-7/8 (403) 16 (406)
080--- 12 / 036080 17-1/2 (445) 15-7/8 (403) 16 (406)
080--- 16 / 048080 17-1/2 (445) 15-7/8 (403) 16 (406)
100--- 16 / 048100 21 (533) 19-3/8 (492) 19-1/2 (495)
100--- 20 / 060100 21 (533) 19-3/8 (492) 19-1/2 (495)
120--- 20 / 060120 24-1/2 (622) 22---7/8 (581) 23 (584)
Fig. 2 -- Dimensional Drawing
352AAV

Table of Contents

Other manuals for Bryant 352AAV

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bryant 352AAV and is the answer not in the manual?

Bryant 352AAV Specifications

General IconGeneral
BrandBryant
Model352AAV
CategoryFurnace
LanguageEnglish

Related product manuals