6
PHYSICAL DATA (CONT)
UNIT SIZE 48090 48115 48130 60090 60115 60130
NOMINAL CAPACITY (ton) 4 4 4 5 5 5
NOMINAL HEATING INPUT (Btu/hr) 90,000 115,000 130,000 90,000 115,000 130,000
SHIPPING WEIGHT** lb
SHIPPING WEIGHT** kg
428
194
428
194
428
194
450
204
450
204
450
204
COMPRESSORS
Quantity
Scroll
1
REFRIGERANT (R --- 410A)
Quantity lb
Quantity (kg.)
6.4
2.9
6.4
2.9
6.4
2.9
10.0
4.5
10.0
4.5
10.0
4.5
REFRIGERANT METERING DEVICE TXV
OUTDOOR COIL
Rows...Fins/in.
Face Area (sq ft)
1...21
15.5
1...21
15.5
1...21
15.5
2...21
15.5
2...21
15.5
2...21
15.5
OUTDOOR FAN
Nominal Cfm
Diameter in.
Diameter (mm)
Motor Hp (Rpm)
4000
26
660.4
1/5 ( 810)
4000
26
660.4
1/5 ( 810)
4000
26
660.4
1/5 ( 810)
3200
26
660.4
1/5 ( 810)
3200
26
660.4
1/5 ( 810)
3200
26
660.4
1/5 ( 810)
INDOOR COIL
Rows...Fins/in.
Face Area (sq ft)
3...17
4.7
3...17
4.7
3...17
4.7
3...17
5.7
3...17
5.7
3...17
5.7
INDOOR BLOWER
Nominal Cooling Airflow (Cfm)
Size in.
Size (mm)
Motor HP (RPM)
1600 1600 1600 1750 1750
11x10
279.4x254
1.0 (1075)
11x10
279.4x254
1.0 (1075)
11x10
279.4x254
1.0 (1075)
11x10
279.4x254
1.0 (1040)
11x10
279.4x254
1.0 (1040)
1750
11x10
279.4x254
1.0 (1040)
FURNACE SECTION*
Burner Orifice No.
Natural Gas Qty...Drill Size (Factory Installe d)
Propane Gas
3...38
3...53
3...33
3...51
3...31
3...49
3...38
3...53
3...33
3...51
3...31
3...49
HIGH-- PRESSURE SWITCH
(psig) Cut-- out Reset (Auto)
650 +/-- 15
420 +/-- 25
LOSS--OF--CHARGE / LOW--PRESSURE
SWITCH (Liquid Line) (psig) cut--out Reset
(auto)
20 +/-- 5
45 +/-- 10
RETURN--AIR FILTERS Throwaway†} in.
(mm)
24x36x1
610x914x25
*Based on altitude of 0 to 2000 ft ( 0 ---610 m).
{ Required filter sizes shown are based on the larger of the AHRI (Air Conditioning, Heating and Refrigeration Institute) rated cooling airflow or the heatin g
airflow velocity of 300 ft/minute for throwaway type. Air filter pressure drop for non---standard filters must not exceed 0.08 IN. W.C.
} If using accessory filter rack refer to the filter rack installation instructions for correct filter sizes and quantity.
** For 460 volt units, add 14 l bs ( 6.35 kg) to the shipping weight.