—26—
CONDENSER ONLY RATINGS*
See notes on page 27.
SST
°F
CONDENSER ENTERING AIR TEMPERATURES °F
55 65 75 85 95 105 115
597C018-F, G
30
TCG 16.5 15.8 15.0 14.2 13.4 12.6 11.7
SDT 75.0 85.0 95.0 105.0 115.0 125.0 135.0
KW 0.781 0.900 1.03 1.18 1.35 1.52 1.71
35
TCG 18.2 17.4 16.6 15.8 14.9 14.0 13.1
SDT 75.1 85.1 95.1 105.0 115.0 125.0 135.0
KW 0.781 0.901 1.03 1.18 1.35 1.53 1.72
40
TCG 20.0 19.2 18.3 17.4 16.5 15.5 14.6
SDT 75.3 85.3 95.3 105.0 115.0 125.0 135.0
KW 0.784 0.904 1.04 1.19 1.35 1.53 1.73
45
TCG 21.9 21.0 20.1 19.1 18.1 17.1 16.1
SDT 76.1 86.0 96.0 106.0 116.0 126.0 136.0
KW 0.794 0.913 1.05 1.20 1.36 1.54 1.74
50
TCG 23.9 22.9 21.9 20.9 19.9 18.8 17.7
SDT 77.0 86.9 96.9 107.0 117.0 127.0 137.0
KW 0.806 0.924 1.06 1.21 1.38 1.56 1.76
55
TCG 26.0 25.0 23.9 22.8 21.7 20.6 19.4
SDT 78.3 88.1 98.0 108.0 118.0 128.0 138.0
KW 0.822 0.941 1.07 1.23 1.39 1.58 1.78
597C024-F, G
30
TCG 21.5 20.6 19.5 18.4 17.3 16.2 15.2
SDT 75.0 85.0 95.0 105.0 115.0 125.0 135.0
KW 1.19 1.34 1.50 1.68 1.87 2.08 2.33
35
TCG 23.6 22.8 21.7 20.6 19.4 18.2 17.0
SDT 75.0 85.0 95.0 105.0 115.0 125.0 135.0
KW 1.17 1.32 1.49 1.67 1.86 2.08 2.32
40
TCG 25.9 25.0 24.0 22.9 21.6 20.3 19.0
SDT 75.0 85.0 95.0 105.0 115.0 125.0 135.0
KW 1.15 1.30 1.47 1.65 1.85 2.07 2.31
45
TCG 28.2 27.4 26.4 25.3 24.0 22.6 21.2
SDT 75.0 85.0 95.0 105.0 115.0 125.0 135.0
KW 1.12 1.28 1.45 1.63 1.84 2.06 2.30
50
TCG 30.6 29.9 28.9 27.8 26.5 25.1 23.6
SDT 75.0 85.1 95.1 105.0 115.0 125.0 135.0
KW 1.10 1.25 1.42 1.61 1.82 2.04 2.29
55
TCG 33.2 32.4 31.5 30.4 29.1 27.6 26.1
SDT 75.4 85.3 95.3 105.0 115.0 125.0 135.0
KW 1.07 1.22 1.39 1.59 1.80 2.03 2.27
597C030-F, G
30
TCG 27.5 26.3 25.0 23.7 22.4 20.9 19.4
SDT 75.0 85.0 95.0 105.0 115.0 125.0 135.0
KW 1.41 1.65 1.91 2.20 2.52 2.86 3.22
35
TCG 30.3 29.0 27.7 26.3 24.8 23.3 21.8
SDT 75.1 85.1 95.1 105.0 115.0 125.0 135.0
KW 1.36 1.60 1.86 2.15 2.48 2.82 3.20
40
TCG 33.3 31.9 30.5 29.0 27.5 25.9 24.2
SDT 75.4 85.3 95.3 105.0 115.0 125.0 135.0
KW 1.32 1.55 1.81 2.11 2.43 2.79 3.17
45
TCG 36.4 35.0 33.4 31.9 30.2 28.6 26.8
SDT 76.1 86.0 96.0 106.0 116.0 126.0 136.0
KW 1.28 1.51 1.78 2.07 2.40 2.75 3.14
50
TCG 39.7 38.2 36.5 34.9 33.1 31.4 29.5
SDT 77.0 86.9 96.8 107.0 117.0 127.0 137.0
KW 1.25 1.48 1.74 2.03 2.36 2.72 3.12
55
TCG 43.2 41.5 39.8 38.0 36.2 34.3 32.3
SDT 78.4 88.1 98.0 108.0 118.0 128.0 138.0
KW 1.22 1.45 1.71 2.00 2.33 2.69 3.09
597C036-F, G
30
TCG 33.4 31.9 30.3 28.7 27.1 25.4 23.6
SDT 75.0 85.0 95.0 105.0 115.0 125.0 135.0
KW 1.76 1.99 2.24 2.52 2.83 3.16 3.52
35
TCG 36.8 35.2 33.5 31.8 30.1 28.3 26.4
SDT 75.4 85.2 95.2 105.0 115.0 125.0 135.0
KW 1.76 1.98 2.23 2.51 2.82 3.16 3.52
40
TCG 40.3 38.6 36.9 35.1 33.2 31.3 29.3
SDT 76.2 86.0 95.9 106.0 116.0 126.0 136.0
KW 1.76 1.98 2.23 2.51 2.82 3.16 3.53
45
TCG 44.0 42.3 40.4 38.5 36.5 34.5 32.3
SDT 77.4 87.1 96.9 107.0 117.0 127.0 137.0
KW 1.77 1.99 2.24 2.52 2.83 3.18 3.55
50
TCG 48.0 46.1 44.1 42.0 39.9 37.8 35.5
SDT 78.9 88.5 98.3 108.0 118.0 128.0 138.0
KW 1.78 2.00 2.26 2.54 2.85 3.19 3.57
55
TCG 52.1 50.1 48.0 45.8 43.6 41.3 38.9
SDT 80.5 90.1 99.7 109.0 119.0 129.0 139.0
KW 1.80 2.02 2.28 2.56 2.87 3.22 3.60