Do you have a question about the Bryant PURON PLUS 598B and is the answer not in the manual?
Brand | Bryant |
---|---|
Model | PURON PLUS 598B |
Category | Air Conditioner |
Language | English |
Protects the coil from weather, vandalism, and incidental hits while allowing airflow.
Units offered in 208/230v single phase with simplified field-stripped lead wire connections.
Available in 4 nominal sizes (024, 036, 048, 060) to meet residential needs.
Galvanized steel cabinet with zinc phosphate and polyester powder coating for durability.
Enhances reliability in adverse weather and ensures dependable performance for many years.
Features accessible panels and a self-diagnostic indicator for efficient service.
Internal overloads and pressure relief valve protect the compressor and refrigerant system.
Five-year limited warranty on all parts, with a 10-year limited warranty on the compressor.
Provides octave band center frequency sound power levels for various unit sizes.
Specifies liquid and vapor tube diameters based on length for optimal performance.
Details unit voltage, ampacity, wire sizing, and fuse/breaker requirements.
Information on compressor type, refrigerant, and metering device.
Specifications for coil face area, fins, motor, airflow, and voltage.
Lists and describes optional accessories like filters and thermostats.
Cooling capacities for 024-A unit with FV4ANF003 indoor section at high speed.
Cooling capacities for 024-A unit with FV4ANB003 indoor section at low speed.
Cooling capacities for 048-A unit with FV4ANB006 indoor section at high speed.
Cooling capacities for 036-A unit with FV4ANB006 indoor section at high speed.
Cooling capacities for 036-A unit with FV4ANB006 indoor section at low speed.
Cooling capacities for 048-A unit with FV4ANB006 indoor section at high speed.
Cooling capacities for 048-A unit with FV4ANB006 indoor section at low speed.
Cooling capacities for 060-A/B units with FV4ANB006 indoor section at high speed.
Cooling capacities for 060-A/B units with FV4ANB006 indoor section at low speed.
Guidelines for unit installation, operating temperatures, and refrigerant line considerations.
Overview of outdoor-mounted, air-cooled, split-system AC unit.
Unit rated per ARI Standard 210 and compliant with ANSI/ASHRAE, UL standards.
Guidelines for unit shipping, storage, and handling per manufacturer recommendations.
Specifies warranty coverage for U.S. and Canada markets.
Factory-assembled unit containing compressor, coil, refrigerant, and controls.
Puron HFC refrigerant with zero ozone depletion potential, EPA SNAP approved.
Galvanized steel, bonderized, powder-coated paint cabinet.
Direct-drive propeller type condenser fan, discharging air upward.
Hermetically sealed compressor mounted on rubber vibration isolators.
Air-cooled coil constructed of aluminum fins mechanically bonded to copper tubes.
Includes shutoff valves, Puron charge, TXV, and high/low pressure switches.
Details unit capacity, suction temp, power consumption, and SEER ratings.
Nominal voltage, frequency, and single-point connection details.
Refers to accessories and available enhancements for specific unit features.