EasyManua.ls Logo

Bryant Preferred 163A User Manual

Bryant Preferred 163A
18 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Installation Instructions
163A / 165A
PREFERREDt SERIES AIR CONDITIONERS
WITH PURON
R
REFRIGERANT
1--1/2 T O 5 NOMINAL T ONS (SIZE 018 TO 060)
TM
the environmentally sound refrigerant
Fig. 1 --- 163A / 165A
NOTE: Read the entire instruction manual before starting the
installation.
TABLE OF CONTENTS
PAGE
SAFETY CONSIDERATIONS 2......................
INSTALLATION RECOMMENDATIONS 2............
INSTALLATION 3--9.14............................
Step 1 -- Check Equipment & Jobsite 3................
Step 2 -- Install on Solid Pad 3......................
Step 3 -- Clearance Requirements 3...................
Step 4 -- Operating Ambient 3.......................
Step 5 -- Install TXV 3 -- 4.........................
Step 6 -- Make Piping Connections 5 -- 7..............
Step 7 -- Make Electrical Connections 7 -- 8............
Step 8 -- Compressor Crankcase Heater 8..............
Step 9 -- Install Electrical Accessories 8..............
Step 10-- Check OCT and OAT thermistor Attachment 8..
Step 11 -- Start-- Up 9..............................
Step 12 -- Check Charge 9, 14.......................
GENERAL SEQUENCE OF OPERATION 10...........
CONTROL FUNCTIONS AND SEQUENCE OF
OPERATION 10 -- 11................................
TROUBLESHOOTING 11 -- 12........................
FINAL CHECKS 13.................................
CARE AND MAINTENANCE 13......................
SUBCOOLING TABLE 14............................
24 VOLT CONNECTION DIAGRAMS 15 -- 16...........
PURONR REFRIGERANT QUICK REF. GUIDE 17.....

Questions and Answers:

Bryant Preferred 163A Specifications

General IconGeneral
BrandBryant
ModelPreferred 163A
CategoryAir Conditioner
LanguageEnglish

Summary

Safety Considerations

Installation Recommendations

Installation

Check Equipment and Job Site

Verify unit, job site conditions, and specifications before proceeding with installation.

Install TXV

Instructions for installing the Thermostatic Expansion Valve (TXV) on rated indoor coils.

Make Piping Connections

Guidance on connecting refrigerant tubing, including proper sizing and filter drier installation.

Evacuate Refrigerant Tubing and Indoor Coil

Procedures for deep vacuum or triple evacuation to remove moisture and contaminants.

Make Electrical Connections

Instructions for safely connecting power and control wiring to the unit.

Compressor Crankcase Heater

Information on powering the crankcase heater before unit start-up.

Check Thermistor Attachments

Ensuring proper attachment of Outdoor Air Temperature (OAT) and Coil Temperature (OCT) thermistors.

Start-Up and Charge Check

Steps for initiating system operation and verifying refrigerant charge.

Deep Vacuum Method

Triple Evacuation Method

Major Components

Control Board

Overview of the functions controlled by the AC control board.

Field Connections

Information on connecting thermostat wires for system operation.

General Sequence of Operation

Control Functions and Sequence of Operation

Sequence of Operation

Describes cooling operation with standard or Evolution controls.

Communication and Status Lights

Explains the meaning of the green COMM and amber STATUS LEDs.

Low Ambient Cooling

Provisions for operating the unit in low outdoor temperatures.

Evolution Controlled Low Ambient Cooling

Standard Thermostat Low Ambient Cooling Mode

Troubleshooting

Systems Communication Failure

Diagnosing issues when communication between system components fails.

Pressure Switch Protection

How high and low-pressure switches protect the compressor.

Control Fault

Action to take if the outdoor unit control board fails.

24V Brown Out Protection

Unit response to low control voltage conditions.

Compressor Thermal Cutout or Loss of 230V Power

Response to compressor thermal overload or power loss.

Temperature Thermistors

Troubleshooting sensor failures for OAT and OCT.

Thermistor Sensor Comparison

Failed Thermistor Default Operation

Status Codes

Final Checks

Care and Maintenance

PuronĀ® (R-410A) Refrigerant Quick Reference Guide