INDOOR UNIT INSTALLATION
Step one: choosing installation location
Step two: install wall-mounting frame
rm it with the client.
1. Hang the wall-mounting frame on the wall; adjust it in horizontal position with the
plastic expansion particles in the holes.
3. Fix the wall-mounting frame on the wall with tapping screws (ST4.2X25TA) and
.
1. Choose the position of piping hole according to the direction of outlet pipe. The
position of piping hole should be a little lower than the wall-mounted frame,
shown as below.
Step three: open piping hole
2. Open a piping hole with the diameter of 2 1/6 in (55mm) 2 3/4 in (70mm)
position.In order to drain smoothly, slant the piping hole on
Left
Wall
Right
Mark in the middle of it
Level meter
Rear piping hole
Wall
Space
to the
wall
above
5 9/10 in
(150mm)
5 9/10 in
(150mm)
Space
to the
wall
above
Rear piping hole
the wall slightly
2 1/6 in (55mm) 2 3/4 in (70mm) 2 1/6 in (55mm) 2 3/4 in (70mm)
-26-