SM619PHA-03 Specifications subject to change without notice. 17
Silence
Press SILENCE on the remote controller to enable the SILENCE
function. While this function is active, the indoor unit runs at faint
breeze (1% fan speed), which reduces noise to the lowest possible
level.
Occupancy Sensor (Sizes 09K-12K)
With the built-in infrared sensor, the indoor unit detects human
movement. The compressor operates in a low frequency if you leave
the room for 30 minutes. The compressor operates in a lower
frequency if you leave the room for 120 minutes, and resumes
automatically when you come back, which helps save energy.
Information Inquiry
To enter information inquiry status, complete the following procedure
within ten seconds:
• Press LED 3 times.
• Press SWING 3 times. If successful, you will hear beeps for two
seconds.
• Use LED and SWING to cycle through the information displayed.
• Press LED to display the next code in the sequence.
• Press SWING to display the previous code.
Table 9 displays the information codes. The screen displays the code
for two seconds, then the information for 25 seconds.
Table 9 — Information Codes
DISPLAYED CODE EXPLANATION ADDITIONAL NOTES
T1 T1 T1 temperature
T2 T2 T2 temperature
T3 T3 T3 temperature
T4 T4 T4 temperature
TP TP TP temperature
Targeted Frequency FT Targeted Frequency
Actual Frequency TR Actual Frequency
Compressor Current dL N/A
Outdoor AC Voltage UO N/A
Indoor capacity test Sn N/A
Reserve -- Running mode
Outdoor Fan Speed Pr Outdoor fan speed
EXV opening angle LR EXV opening angle
Indoor fan speed IR Indoor fan speed
Indoor humidity HU N/A
Adjusted setting temperature TT N/A
Indoor dust concentrations DT N/A
WIFI signal strength IF N/A
GA algorithm frequency OT N/A