EasyManuals Logo

Bryant A180218B User Manual

Bryant A180218B
94 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #45 background imageLoading...
Page #45 background image
45
A13228
System in Control: The system will decide which stage should be
running to satisfy the heating demand.
High Heat: Temperature below which only the high stage of heating
will be energized.
Only Low Heat: The system will only run in low stage heating.
6.3.4.2. Cooling Lockout
Outside temperature below which cooling will not be provided. After the
selection is made, touch SAVE.
Cooling Lockout Temp: None, 45, 50 or 55 (°F). Default = None
NOTE: When simultaneous heating and cooling demand feature is on,
the cooling lockout shall be ignored.
6.3.4.3. Defrost Interval
Time interval at which defrost cycles can occur on a heat pump. AUTO
means the defrost interval is optimized by the outdoor control. After the
selection is made, touch SAVE.
Set Defrost Interval: 30, 60, 90, 120 minutes or AUTO. Default =
AUTO
NOTE: See Heat Pump Installation Instructions for Defrost Timing
Interval when using AUTO Defrost.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bryant A180218B and is the answer not in the manual?

Bryant A180218B Specifications

General IconGeneral
BrandBryant
ModelA180218B
CategoryThermostat
LanguageEnglish

Related product manuals