ACCESSORY LIST
ACCESSORY KITS DESCRIPTION
SUGGESTED AND REQUIRED USE
1.
Disconnect Kit
The kit is used to disconnect electrical power to the fan coil so service or maintenance may be performed safely.
SUGGESTED USE: FE4 units with 3- through 10-kW electric resistance heaters and cooling controls.
2.
Downflow Conversion Kit
Fan coils are shipped from the factory for upow or horizontal-left applications. Downow conversion kits provide proper condensate water
drainage and support for the coil when used in downow applications. Separate kits are available for slope coils and A-coils.
REQUIRED USE:
This kit must be used whenever FE4 fan coils are used in downow applications.
3.
Downflow Base Kit
This kit is designed to provide a 1-in. minimum clearance between unit discharge plenum, ductwork, and combustible materials. It also provides
a gap free seal with the oor.
REQUIRED USE:
This kit must be used whenever FE4 fan coils are used in downow applications.
4.
Single-Point Wiring Kit
The single-point wiring kit acts as a jumper between L1 and L3 lugs, and between L2 and L4 lugs. This allows the installer to run 2 heavy-gage,
high-voltage wires into the fan coil rather than 4 light-gage, high-voltage wires.
SUGGESTED USE: FE4 fan coils with 15- and 20-kW fused heaters only.
5.
Air Cleaner 240-Volt Conversion Kit
The AIRA electronic air cleaner comes ready for 115-v operation.
REQUIRED USE:
This kit is required when running 240-volt circuit to air cleaner.
6.
Airflow Sensor Kit (Air Cleaner)
The airow sensor kit ensures the FE4 fan coil and electronic air cleaner work as a system.
REQUIRED USE:
This kit is required whenever an electronic air cleaner is used with an FE4 fan coil.
7.
Fan Coil Filter
Kit shipped from factory with 12 fan coil framed lters. These lters collect large dust particles from the return air entering the fan coil and prevents
them from collecting on the coil. This process helps to keep the coil clean, which increases heat transfer and in turn the efciency of the system.
SUGGESTED USE: For replacing factory-supplied lters (same lters).
8.
Condensate Drain Trap Kit
This kit consists of 50 PVC condensate traps. Each trap is pre-formed and ready for eld installation. This deep trap helps the system make and
hold proper condensate ow even during blower initiation.
SUGGESTED USE: FE4 fan coils.
9.
Downflow/Horizontal Conversion Gasket Kit
This kit provides the proper gasketing of units when applied in either a Downow or Horizontal application.
REQUIRED USE:
FE4 fan coils.
ITEM ACCESSORY PART NO. FAN COIL SIZE USED WITH FE4A
Disconnect Kit KFADK0201DSC Cooling controls and heaters through 10-kW
Downow Conversion Kit (Slope) KFADC0201SLP 003
Downow Conversion Kit (A-coil) KFADC0401ACL 002, 005, 006
Downow Base Kit KFACB0201CFB 002
KFACB0301CFB 003, 005
KFACB0401CFB 006
Filter Kit (12 Pack) KFAFK0212MED 002
KFAFK0312LRG 003, 005
KFAFK0412XXL 006
Single-Point Wiring Kit KFASP0101SPK Only with 15- and 20-kW Fused Heaters
Airow Sensor Kit (Air Cleaner) KEAAC0101AAA All
Air Cleaner 240-Volt Conversion Kit KEAVC0201240 All
PVC Condensate Drain Trap Kit (50 Pack) KFAET0150ETK All
Downow/Horizontal Conversion Gasket Kit KFAHD0101SLP All