EasyManuals Logo

Bryant fe4anf005 User Manual

Bryant fe4anf005
16 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #6 background imageLoading...
Page #6 background image
6
PERFORMANCE DATA
AIRFLOW DELIVERY — COOLING, HEATING, ELECTRIC HEATING MODES
AIRFLOW PERFORMANCE - AVAILABLE EXTERNAL STATIC PRESSURE
FAN COIL
MODEL AIRFLOW DELIVERY
AVAILABLE STATIC
PRESSURE
FE4ANF002
525 CFM
700 CFM
875 CFM
1050 CFM
1.00 IN. H2O
1.00 IN. H2O
1.00 IN. H2O
0.80 IN. H2O
FE4ANF003
700 CFM
875 CFM
1050 CFM
1225 CFM
1.00 IN. H2O
1.00 IN. H2O
1.00 IN. H2O
1.00 IN. H2O
FE4ANF005
875 CFM
1050 CFM
1225 CFM
1400 CFM
1.00 IN. H2O
1.00 IN. H2O
1.00 IN. H2O
1.00 IN. H2O
FE4ANB006
1050 CFM
1225 CFM
1400 CFM
1750 CFM
1.00 IN. H2O
1.00 IN. H2O
1.00 IN. H2O
1.00 IN. H2O
The FE4 fan coil will provide airow at a rate that is requested by
the Integrated System User Interface during Air Conditioning or
Heat Pump Heating (without electric heat) modes. The nominal
airow for both heating and cooling modes is 350 cfm/ton
nominal refrigeration size of the outdoor unit installed. The
airow actually requested by the User Interface is modied by its
internal algorithms for zoning, comfort or efciency concerns.
Refer to the documentation for the User Interface for more
information on how the User Interface controls the fan coil. Safe
operation of electric heaters requires airow delivery at or above
the minimum CFM for electric heater application listed in the
chart below. The fan coil will adjust its airow delivery to maintain
safe airow as operating mode and staging conditions require.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bryant fe4anf005 and is the answer not in the manual?

Bryant fe4anf005 Specifications

General IconGeneral
BrandBryant
Modelfe4anf005
CategoryAir Handlers
LanguageEnglish

Related product manuals