Residential Air Conditioners and Heat Pumps Using R-22 and Puron® Refrigerant: Application Guideline and Service Manual
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
5
Accessories
Table 1 – Required Field-Installed Accessories for Air Conditioners
ACCESSORY
REQUIRED FOR LOW-AMBIENT
COOLING APPLICATIONS
(Below 55°F/12.8°C)
REQUIRED FOR
LONG LINE
APPLICATIONS
*
*. For tubing line sets between 80 and 200 ft. (24.38 and 60.96 m) and/or 35 ft. (10.7 m) vertical differential, refer to Residential Piping and Longline Guideline.
REQUIRED FOR
SEA COAST
APPLICATIONS
(Within 2 miles/3.22 km)
Ball Bearing Fan Motor
Yes
†‡
†. Additional requirement for Low-Ambient Controller (full modulation feature) MotorMasterr Control.
‡. Evolution 2-stage units come standard with this accessory.
No No
Compressor Start Assist Capacitor and Relay
Yes
**
**.Not required on 2-stage
Yes No
Crankcase Heater
Yes
Yes
No
Evaporator Freeze Thermostat
Yes
No No
Hard Shut-Off TXV Yes Yes Yes
Liquid Line Solenoid Valve No No No
Motor Master or Low-ambient Pressure Switch
Yes
No No
Support Feet Recommended No Recommended
Winter Start Control
Yes
No No
Table 2 – Required Field-Installed Accessories for Heat Pumps
ACCESSORY
REQUIRED FOR LOW-AMBIENT
COOLING APPLICATIONS
(Below 55°F / 12.8°C)
REQUIRED FOR
LONG LINE
APPLICATIONS
*
*. For tubing line sets between 80 and 200 ft. (24.38 and 60.96 m) and/or 20 ft. (6.09 m) vertical differential, refer to Residential Piping and Longline Guideline.
REQUIRED FOR
SEA COAST
APPLICATIONS (Within 2
miles / 3.22 km)
Accumulator Standard Standard Standard
Ball Bearing Fan Motor
Yes
†‡
†. Additional requirement for Low-Ambient Controller (full modulation feature) MotorMasterr Control.
‡. Evolution 2-stage units come standard with this accessory.
No No
Compressor Start Assist Capacitor and Relay
Yes
**
**.Not required on 2-stage
Yes No
Crankcase Heater
Yes
Yes
No
Evaporator Freeze Thermostat
Yes
No No
Hard Shutoff TXV Yes Yes Yes
Isolation Relay Yes No No
Liquid Line Solenoid Valve No
See Long-Line Application
Guideline
No
Motor MasterÒ Control or
Low Ambient Switch
Yes
No No
Support Feet Recommended No Recommended