Manual EVoBASIC v.7 77 / 80
connected.
Check the cell connection and
ensure that cables and
connection
terminals are in good
condition.
completely worn down.
Check the condition of the cell
electrodes, and replace
it if any
damage is observed.
very low salt
Ensure that the water has salt
and that it is dissolved.
incorrectly connected or
damaged
Check the cabling of the probe
and the probe itself. Check 5.1.
It can
work in manual mode if
necessary.
redox potential.
Leave the equipment to chlorate
in manual mod
hours.
Check the chemical balance of
have a
probe and is in
"automatic mode".
Install a Redox or Free Chlorine
probe, or configure "manual"
mode.
4.3- Operation time
It may be useful to see the operation times for regular maintenance
operations. From the main screen, press both buttons at the same
time.
4.4- Electrolysis cell life
The electrolysis cells from our units are designed to reach a
lifespan of 10.000 hours (10K models) and 5.000 hours (5k models).
However, this lifespan is directly related with the quality of the water and
specially with the correct use of the equipment. Please, read the
following suggestions in order to guarantee that your cell reaches the
specified lifespan.
Salt concentration: It is very important that the water of your
swimming pool has a sufficient salt concentration, otherwise the cell will
degrade prematurely if you keep it working permanently in low salt