59
eFax 2000 - Edition 4 – 14th November ’00 (3313)
Optional settings
The User Function options are:
01: MCF (SINGLE LOC) ON or OFF
Switch on to print a Confirmation Report for each
fax sent and received. Original setting = OFF.
02: MCF (MULTI-LOC.) ON or OFF
Switch on to print a Broadcast Confirmation Report
every time a fax is sent to a group or multiple
destinations. Original setting = OFF.
03: ERR. REPORT (MCF.) ON or OFF
Switch on to print a Message Confirmation Report
each time there is an error on an incoming or
outgoing fax. Original setting = ON.
04: IMAGE IN MCF ON or OFF
Switch on to add a section of the first page your
machine printed as a useful reference underneath a
Message Confirmation Report. Original setting = ON.
05: SENDER ID ON or OFF
When switched on, your machines ID, date and
time is printed on each page you send. Original
setting = ON.
06: MONITOR VOLUME HIGH, LOW, OFF
You can set the volume for the telephone line and
fax tones you hear. Original setting = HIGH.
You can change the settings on your eF@x 2000 to
suit your personal preferences.
For
04: IMAGE IN MCF
to work, the function
17: MEM/FEEDER SW
must be set to MEM and function
25: INSTANT DIALLING
must be switched On.
To change the User Function settings
Press SELECT FUNCTION.
Press
USER PROG.
Display shows
1: FUNC. PROGRAMMING
Press YES.
Display shows
FUNCTION NO. [ ]
Enter the 2-digit number of the function you
want to change. Display shows the name of
the function.
Press
NO to scroll through the options.
Press
YES to select the option displayed.
Press
STOP to select another function.
Or
Press SELECT FUNCTION to return to
standby.
SELECT
FUNCTION
SELECT
FUNCTION
USER
PROG.
YES
NO
YES
STOP