TROUBLESHOOTING (cont.)
Water leak filling drip tray or around
dispense deck area
Water leaking beneath machine
1. Initial fill/setup
2. Dispense deck
3. Water pressure greater than
100psi
1. Bath tank overflow.
2. Condensation from cabinet cool-
ing coil.
Some expansion normal. May fill
drip tray during initial ice block
formation
Inspect or replace fittings clamps,
o-rings, solenoids and quick discon-
nect fittings.
NOTE: Dispense deck area slopes to
drain tube that leads to the drip tray.
Install water pressure regulator and
reduce to 50 psi.
A) Check all internal water connec-
tions.
B) Check internal plumbing con-
nections.
C) Check bath float switch
Check for routing of condensation
tube to water bath.