SERVICE (cont.)
P833
Location:
The limit thermostat is located inside the hood on
the tank lid just to the left of the tank heater.
Test Procedure:
1. Disconnect the brewer from the power supply.
2. Disconnect both black wires from the limit ther-
mostat.
3. With an ohmmeter, check for continuity across
the limit thermostat terminals.
If continuity is present as described, reconnect the black
wires to the limit thermostat , the limit thermostat is
operating properly.
If continuity is not present as described, press the reset
button on the limit thermostat and repeat step #3.
After repeating step #3, if no continuity is shown,
replace the limit thermostat.
1
2
3
4
5
.5
MINUTES
BUNN-O-MATIC
P/N 262
0- 120 VAC
START ON / WARMER
SELECTOR READY
CAU
TION
HOT
WATER
LIMIT THERMOSTAT
P819
27038 030901
FIG. 16 LIMIT THERMOSTAT
FIG. 17 LIMIT THERMOSTAT TERMINALS
Removal and Replacement
1. Remove all wires from the limit thermostat termi-
nals.
2. Carefully remove the two #8-32 nuts securing
the limit thermostat to tank lid and remove limit
thermostat.
3. Carefully secure new limit thermostat to tank
lid.
4. Refer to Fig. 17 when reconnectng the wires.
BLK to Terminal
Block (Black Insert)
BLK to Tank Heater
(Left Terminal)
BLK to Contactor Ter-
minal