SPECIFICATIONS
6.1 SPECIFICATIONS
Specification in relation to the process
Flow measurement
Measurement type Electromagnetical measurement
Measuring range 0,05 to 10 m/s (0.15 to 32.8 fps)
Measuring error 1) with individual works calibration (on request) or Teach-In:
+/- 2 % o. R. (1-10 m/s) (*)
2) with standard mean K-Factor:
+/- 4 % o. R. (1-10 m/s) (*)
Linearity +/- (1 % o. R. + 0,1% o. F.S.) (*)
Repeatability 0.25 % of measured value
Piping installation
Pipes Stainless steel, brass or plastic (PVDF, PP, PVC)
Connection Solvent/fusion spigots, threaded ports (G, NPT, Rc),
buttwelding ends, flange, Tri-clamp - see instruction manual
S020 - Ident. No.- 429633S
Pressure rating PN 6
Fluid temperature 0 to 80 °C (32 to 176°F)
Conductivity of the fluid min. 20 mS/cm
Materials contacting the fluid: Sensor housing : PVDF
Electrodes : Stainless-steel 316L (1.4404)
Earth ring : Stainless-steel 316L (1.4404)
Seals : FPM/EPDM
Specificaton in relation to the control outputs
Electrical connection
Power supply 18-30 VDC regulated (oscillation rate £+/- 5%)
Consumption 8045 without relay : 60 mA
8045 with relays : 100 mA
Proportional output
Output type Current output from 4-20 mA (error signal 22mA)
Accuracy Dependent on the measuring error - Maximum of 4%
Wiring Sinking or sourcing mode
Response time 0,5 s to 150 s depending on the filter to reach 95% of a
variation
Maximum Load (current loop) 1300 W at 30 VDC
1000 W at 24 VDC
700 W at 18 VDC
Pulse output
Output type Isolated NPN / PNP open collector
Specifications 30VDC max / 100mA max
Relay output
Output type Normally open relays
Relay output 2 relays, freely adjustable
AC : 250V / 3A
DC : 30V / 3A (resistive load)
Max. cutting power : 750 VA (resistive load)
Life expectancy 100 000 cycles (minimum)
Thresholds Hysteresis programmable according to the temperature or flow
6.1