EasyManuals Logo

BUSCH R 5 RD 0200 A User Manual

BUSCH R 5 RD 0200 A
28 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #11 background imageLoading...
Page #11 background image
Installation | 5
0870572700_RD0200-0360A_-0003_IM_en 11 / 28
To reduce the maintenance effort and ensure a long product lifetime we recommend
the following cooling water quality:
Hardness mg/l (ppm) < 90
Properties Clean & clear
PH value 7 … 8
Particle size µm < 200
Chloride mg/l < 100
Electrical conductivity µS/cm 100
Free chloride mg/l < 0.3
Materials in contact with the cooling water Stainless steel, copper and cast iron
NOTE
Water hardness unit conversion.
1 mg/l (ppm) = 0.056 °dh (german degree) = 0.07 °e (english degree) = 0.1 °fH (french
degree)
5.3 Filling Oil
NOTICE
Use of an inappropriate oil.
Risk of premature failure!
Loss of efficiency!
Only use an oil type which has previously been approved and recommended by
Busch.
For oil type and oil capacity see Technical Data [25] and Oil [25].
1
4
MAX
MIN
3
2
Busch Oil
Check oil level
1x o-ring, part no.:
see "Service kit" (Spare Parts)

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the BUSCH R 5 RD 0200 A and is the answer not in the manual?

BUSCH R 5 RD 0200 A Specifications

General IconGeneral
TypeRotary vane pump
Ultimate Vacuum0.1 mbar
Ultimate pressure0.1 mbar (0.075 Torr)
Gas typeAir, non-corrosive gases
Frequency50 Hz