EasyManua.ls Logo

BUSCH R 5 RA 0250 D - User Manual

BUSCH R 5 RA 0250 D
28 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
O
2
Instruction Manual
R 5 Oxygen
Oil-Lubricated Rotary Vane Vacuum Pumps
RA 0160 D, RA 0202 D, RA 0250 D, RA 0302 D
(Version intended for OEM only)
0870573103/-0001_en / Original instructions / Modifications reserved 30/05/2017
Ateliers Busch S.A.
Zone industrielle, 2906 Chevenez
Switzerland

Questions and Answers

  • J
    Jamie SmithAug 8, 2025
    Why does my BUSCH R 5 RA 0250 D Water Pump run too hot?
    • I
      ibradfordAug 8, 2025
      If your BUSCH Water Pump runs too hot, it could be due to several reasons. First, remove any dust and dirt from the machine to ensure sufficient cooling. Also, make sure that the ambient temperature is within the permitted range. Check the oil level and top up if it's too low. Finally, if the exhaust filters are partially clogged, replace them.
  • R
    ryanberryAug 14, 2025
    What to do if my BUSCH R 5 RA 0250 D Water Pump does not reach the usual pressure?
    • D
      Douglas ThompsonAug 14, 2025
      If your BUSCH Water Pump is not reaching its usual pressure, the oil level might be too low, so top it up. Also, the inlet screen could be partially clogged; clean it. If you have an optional inlet filter cartridge, it might be clogged and needs replacement. If none of these resolve the issue, the internal parts may be worn or aged, and you should contact Busch for repair.
  • D
    Dr. Desiree Humphrey DDSAug 20, 2025
    Why is my BUSCH R 5 RA 0250 D Water Pump fuming or expelling oil?
    • L
      Lori HowellAug 20, 2025
      If your BUSCH Water Pump is fuming or expelling oil droplets through the gas discharge, the exhaust filters may be partially clogged, so replace them. Also, ensure the correct position of the exhaust filters and the O-rings. Check the float valve and the oil pipe for any clogging, and remove any blockages found.
  • B
    brandon33Aug 27, 2025
    How to fix a BUSCH R 5 RA 0250 D Water Pump that does not start?
    • J
      Joseph GilmoreAug 27, 2025
      If your BUSCH Water Pump does not start, check the power supply to ensure the motor is getting power. If the motor is defective, replace it. Also, inspect the coupling; if it's defective, replace it as well.
  • K
    Kenneth HernandezSep 2, 2025
    Why is my BUSCH R 5 RA 0250 D Water Pump running very noisily?
    • A
      Amy DavisSep 2, 2025
      If your BUSCH Water Pump runs very noisily, the coupling might be defective and needs replacement. Alternatively, the vanes could be stuck, or the bearings might be defective. In the latter two cases, contact Busch for repair.

Summary

Safety

Product Description

Transport

Installation

Installation Conditions

Specifies required ambient conditions, space, ventilation, and protection class for safe and effective installation.

Filling Oil

Instructions for filling the machine with the correct type of oil, including warnings about using unapproved oils and lead seal procedures.

Electrical Connection

Details electrical connection requirements and safety warnings, including wiring diagrams for three-phase motors.

Commissioning

Maintenance

Oil and Oil Filter Change

Provides instructions for changing the oil and oil filter, emphasizing the use of approved oil and correct lead seal procedures.

Overhaul

Spare Parts

Troubleshooting

Technical Data

BUSCH R 5 RA 0250 D Specifications

General IconGeneral
Motor Power5.5 kW
Weight260 kg
TypeRotary Vane Pump
Voltage230 V
Frequency50 Hz