Instruction Manual
R 5
Oil-Lubricated Rotary Vane Vacuum Pumps
RA 0760 A PLUS
0870215096/-0001_en / Original instructions / Modifications reserved 17/05/2019
Ateliers Busch S.A.
Zone industrielle, 2906 Chevenez
Switzerland

Other manuals for BUSCH R 5 series

Questions and Answers

  • W
    William RomeroSep 23, 2025
    What to do if my BUSCH R 5 runs very noisily?
    • J
      James MurraySep 23, 2025
      If your BUSCH Water Pump is running very noisily, it could be due to a few reasons. The coupling (CPL) might be worn and need replacement. Alternatively, the vanes could be stuck, or the bearings could be defective. For stuck vanes or defective bearings, contact Busch for machine repair.
  • P
    pammartinezAug 23, 2025
    Why does my BUSCH Water Pump have abnormal oil consumption?
    • J
      Jeffrey DunnAug 25, 2025
      Abnormal oil consumption in your BUSCH Water Pump can stem from a few issues. Oil leaks could be the problem, in which case the seals need replacement (contact Busch). Another potential cause is a malfunctioning float valve (FV), requiring a check of the valve and oil return line, and repair if necessary (contact Busch). Lastly, operating the machine at atmospheric pressure for extended periods can lead to this issue, so ensure the machine operates under vacuum.
  • T
    Tyler PriceAug 25, 2025
    Why is the oil in my BUSCH R 5 Water Pump emulsified?
    • J
      Jessica GilbertAug 26, 2025
      If the oil in your BUSCH Water Pump is emulsified, it could be because the machine sucked in liquids or significant amounts of vapor, in which case you should flush the machine (contact Busch). Another cause may be that you need to clean the filter of the gas ballast valve (GB). You might also need to modify the operational mode (see Conveying Condensable Vapours).
  • B
    brianna12Aug 27, 2025
    What causes emulsified oil in a BUSCH R 5 Water Pump?
    • J
      Jennifer CrawfordAug 27, 2025
      If the oil in your BUSCH Water Pump is emulsified, it could be because the machine sucked in liquids or significant amounts of vapour, in which case you should contact Busch to flush the machine. You may also need to clean the filter of the gas ballast valve (GB) or modify the operational mode.
  • M
    Michael RobbinsAug 27, 2025
    Why my BUSCH R 5 does not start?
    • A
      Anna WilsonAug 27, 2025
      If your BUSCH Water Pump isn't starting, there are a few potential causes. First, the motor might not be getting the right voltage, so check the power supply. Alternatively, the motor itself could be defective and need replacement. Finally, the coupling (CPL) may be defective, requiring replacement.
  • J
    Jessica RossSep 16, 2025
    What causes communication problems with my remotely controlled BUSCH R 5?
    • R
      Rachel FreemanSep 16, 2025
      Communication problems with your remotely controlled BUSCH Water Pump can arise from: * A cut or disconnected wire. * Improper connection. * Incorrect settings between the machine and the network. Check the wiring between the machine and the network and verify the remote control parameters.
  • J
    Joshua KennedySep 13, 2025
    Why doesn't my BUSCH Water Pump reach usual suction pressure?
    • V
      Victoria LaneSep 13, 2025
      If your BUSCH Water Pump isn't reaching the usual suction pressure, check the following: * The oil level might be too low; top up the oil. * The inlet filter cartridge may be partially clogged; replace it. * Internal parts may be worn or damaged.
  • L
    Laurie StoneSep 14, 2025
    Why doesn't my BUSCH R 5 Water Pump reach target pressure?
    • C
      Christopher WoodsSep 15, 2025
      If your BUSCH Water Pump isn't reaching the target pressure, it could be because the machine is over or undersized for the application, or there are leaks or pressure drops in the pipework upstream of the suction connection. Check the system pipework.
  • C
    Christina BrownSep 5, 2025
    What to do if my BUSCH R 5 is running very noisily?
    • V
      Vicki JoyceSep 5, 2025
      If your BUSCH Water Pump is running very noisily, the coupling (CPL) may be worn and needs replacement. For issues like stuck vanes or defective bearings, repair of the machine is needed (contact Busch).
  • J
    jeffrey72Sep 3, 2025
    What to do if my BUSCH R 5 Water Pump does not start?
    • T
      Tyler WilliamsSep 3, 2025
      If your BUSCH Water Pump doesn't start, there could be several reasons. First, check the power supply to ensure the motor is getting power. If the power supply is fine, the motor itself might be defective and require replacement. Another possibility is a defective coupling (CPL), which would also need to be replaced.

Summary

Safety

Product Description

Installation

Installation Conditions

Specifies requirements for the installation environment, space, and mounting.

Filling Oil

Instructions on using the correct oil type and checking the oil level via sight glass.

Electrical Connection

Details on connecting the machine to the power supply, emphasizing safety and compatibility.

Commissioning

Prerequisites Before Use

Lists essential checks before starting the machine, including installation conditions and power status.

Configuration Settings

Explains how to configure machine parameters like control mode, operating mode, and ecomode.

Machine Start-Up

Step-by-step guide for starting the machine, including safety precautions and monitoring.

In Operation

Control Mode Selection

Describes how to access and select control modes like Local/Manual, Local/Auto, and Remote/Auto.

Operating Mode Selection

Details how to select between Speed Control and Pressure Control operating modes.

Monitoring Functions

Dysfunction and Troubleshooting

Warning and Alarm Thresholds

Explains warning and alarm signal levels and lists default thresholds for various parameters.

Warning;Alarm Acknowledgment

Details the procedure for acknowledging warning/alarm signals after a problem is rectified.

Maintenance Schedule

Maintenance Schedule

Outlines recommended maintenance tasks and intervals for normal and harsh applications.

Oil Level Inspection

Details how to check the oil level status via the interface and visual sight glass.

Oil and Oil Filter Change

Instructions for changing the oil and oil filter, emphasizing correct oil type and procedures.

Exhaust Filter Change

Step-by-step guide for replacing the exhaust filters, including part numbers and torque specifications.

Troubleshooting Guide

General Problems and Solutions

Addresses common issues like machine not starting, with possible causes and remedies.

User Interface Messages Troubleshooting

Explains messages and alarms displayed on the user interface and their corresponding solutions.

Technical Data

BUSCH R 5 series Specifications