7.4 Gas Ballast Valve Control
The gas ballast valve can be controlled (open/closed position) via a simple switch button.
This operation is only available for “Role 2” people.
To change the state of the gas ballast valve:
• Go to “OPERATIONS” > “PARAMETERS”.
• Stay on the first page.
• Press on the switch button (password required).
HOME
PARAMETERS
OPERATIONS
MODE
MAINTENANCE
SYSTEM
WEEK PLANNER
Gas-ballast valve
Closed
NEXT
Opening range (low pressure)
Opening range (high pressure)
• Define an opening pressure range (low and high pressure).
Gas-ballast valve
Open
Opening range (low pressure)
Opening range (high pressure)
0 mbar
55 mbar
Parameter Default value Adjustment range
Opening range (low pressure) 0 mbar 0 …1199 mbar
Opening range (high pressure) 1000 mbar 1 … 1200 mbar