7.2.2 Pressure Control
The pressure control mode allows the maintenance of a constant pressure level (target
pressure) by automatically adapting the motor frequency. This mode is only available for
“Role 2” people, see Role and User [11].
To switch from speed control to pressure control:
Press on the target pressure value (password required).
Assign the target pressure in the keypad and press “Enter”.
Press on the switch button.
Speed control
Pressure control
Operating mode
On
Off
60 Hz
20 mbar
Parameter Default value Adjustment range
Pressure control (target pressure) 20 <5 … 400 mbar
NOTE
Display of the ultimate pressure.
Due to sensor accuracy, the minimum displayed value of the ultimate pressure is 5
mbar preceded by the symbol "<", which means that the actual value is lower than dis-
played.
The ultimate pressure of the machine is indicated on the nameplate (NP).
7.3 Ecomode
The Ecomode stops the machine when the inlet pressure has reached the preset "eco-
mode pressure" within a defined time delay and will restart once the inlet pressure ex-
ceeds the "restart pressure".
This mode is only available for “Role 2” people, see Role and User [11].
To active and set the Ecomode:
Go to “OPERATIONS” > “MODE”.
Access to the second page.
Press on Ecomode switch button (password required).

Other manuals for BUSCH R 5 series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the BUSCH R 5 series and is the answer not in the manual?

BUSCH R 5 series Specifications

General IconGeneral
BrandBUSCH
ModelR 5 series
CategoryWater Pump
LanguageEnglish

Related product manuals