6 | Commissioning
20 / 56 0870215096_RA0760A_PLUS_-0001_IM_en
6.3 Start Up
CAUTION
During operation the surface of the machine may reach temperatures of more than
70°C.
Risk of burns!
Avoid contact with the machine during and directly after operation.
CAUTION
Noise of running machine.
Risk of damage to hearing!
If persons are present in the vicinity of a non noise insulated machine over extended
periods:
Make sure that ear protection is being used.
To start the machine:
Press and hold the start/stop button (SSB) for at least 3 seconds.
Monitor the operating values (Monitoring [31]) and make sure that they always
comply with the operating conditions, see Technical Data [52].
As soon as a warning/alarm signal occurred:
Investigate the cause of the signal, see Dysfunction [39].
NOTE
Activated oil level signal.
The machine is generally shipped without oil, therefore an alarm signal occurs during
the first start-up.
As soon as the machine has been filled with oil, acknowledge the alarm signal by fol-
lowing the Warning/Alarm Acknowledgment Procedure [40].
NOTE
Control mode “Remote/Auto“.
The machine cannot be started manually if the control mode is set to “Remote/Auto”.

Other manuals for BUSCH R 5 series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the BUSCH R 5 series and is the answer not in the manual?

BUSCH R 5 series Specifications

General IconGeneral
BrandBUSCH
ModelR 5 series
CategoryWater Pump
LanguageEnglish

Related product manuals