2.3 Requirements for the installation location
Always select a suitable location before installation. You shall ensure that the
installation location meets the following conditions:
Sufficient ventilation and dry environment (max humidity is 95%)
The range of room temperature is 0℃ ~ + 40℃
Protected against penetrating water
Always install away from highly flammable (e.g. paper) or explosive materials (e.g.
fuel, paint)
Mounting surface shall be capable for supporting the total weight of the device: 96kg
(3kWh system)
Minimum clearance from the wall (15 cm)
Keep the distribution board at a reasonable distance from the MINI ES system
installation. Only 10m connection cable is provided for each CT. Cable extension
requires extra cost, maximum cable extension is 10 meters
Access authority
Children shall be accompanied by an adult if they are in the installation room
Children shall not operate the storage system
2.4 Safety signs on the device
Be aware of dangerous voltage/ electric shock
The product should not be disposed of together with household
waste at the end of its life.Please send it to a proper institution for
recycle and reuse
Point of connection for grounding protection