FICHE D’INSTRUCTION TECHNIQUE
: V 54 1006
PINCE PNEUMATIQUE CLIC COMPACTE
: C
P
age 14/16
4. PROBLEM RESOLUTION
Problem Causes Solution
Defective trigger or valve
block.
Check compressed air supply
connection as well as trigger and
control valve integrity.
Replace them if necessary
Compressed air leaks around the
hose connection.
Hose not properly fitted in
connector.
Compressed air leaks around the
control valve.
Control valve or O-rings
worn out.
Improper air supply or leaks
Check that pressure complies with
instruction manual and search for
leaks.
Check if the head PN is adapted to the
clamp to clip.
Check the jaw’s closing dimension
Check if the head’s fastening nut is
properly tightened.
Check for clearance in the axes
The jaws do not return to initial
position
Damaged or broken springs
Chips/debris creating
mechanical blocking
Clean with compressed air (blower)