Chapter 2: System Hardware
150
The integrated module meets the low-level static discharge specifications identified in Electromagnetic
compatibility (EMC) compliance and provides internal surge suppression but does not provide lightning
suppression.
Table 113 Force 4525L physical specifications
Category
Specification
Dimensions (Diameter x Depth)
256 mm x 125 mm x 46 mm (10.1 in x 4.9 in. x 1.8 in.)
Weight
1.3 kg (2.9 lbs.)
Table 114 Force 4525L environmental specifications
Category
Specification
Temperature
-30°C to 65°C (-22°F to 149°F)
Wind loading
200 km/hour (124 mph)
Environmental
IPx0
Force 4525L heater
At startup, if the Force 4525L module temperature is at or below 32°F (0°C), an internal heater is
activated to ensure that the device can successfully begin operation. The unit’s heater is only activated
when the unit is powered on and will not apply heat to the device once the startup is complete. When the
unit temperature is greater than 32°F (0°C), the heater is deactivated and the unit continues its start-up
sequence.
The effect on device startup time at various temperatures is defined in Table 115.
Table 115 Force 4525L startup times based on ambient temperature
InitialTemperature
Startuptime(frompowerontooperational)
-22°F (-30°C) H
20 minutes
-4°F (-20°C)
6 minutes
14°F (-10°C)
2 minutes, 30 seconds
Force 4525L wind loading
Ensure that the device and the structure on which it is mounted are capable of withstanding the
prevalent wind speeds at a proposed ePMP site. Wind speed statistics are available from national
meteorological offices.
The device and its mounting bracket are capable of withstanding wind speeds of up to 180 kph (124
mph).
Wind blowing on the device will subject the mounting structure to significant lateral force. The
magnitude of the force depends on both wind strength and the surface area of the device. Wind loading
is estimated using the following formulae:
Force (in kilograms) = 0.1045aV
2

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cambium Networks Force 4525 and is the answer not in the manual?

Cambium Networks Force 4525 Specifications

General IconGeneral
BrandCambium Networks
ModelForce 4525
CategoryNetwork Hardware
LanguageEnglish

Related product manuals