EasyManua.ls Logo

CAME BX-243 - Installation: Gearmotor Mounting and Alignment; Mounting the Gearmotor and Cable Connections; Adjusting Gearmotor Levelling Feet

CAME BX-243
22 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6
ENGLISH
The data and information shown in this dialogue may be changed by Came Cancelli Automatici S.p.A. at any time without prior warning.
¿MM
Remove the form box (1), fi ll the pit around the cement block with soil (2) and unbolt the nuts and washers from the bolts (3).
The securing plate must be clean, perfectly aligned and with the bolt threads completely on the surface.
Insert the electric cables into the tubes until they exit about 400mm (4).
- Remove the cover from the gearmotor by loosening the side bolts, perforate the cable shafts using a screwdriver or a pair of
scissors and position the gearmotor atop the plate. Careful! The electric cables must pass through the cable shafts.
cable shafts
- Lift the gearmotor from the securing plate by about 5 to 10mm by using the threaded steel-levelling feet to allow any later
adjustments between the pinion and the rack.
Levelling feet
1)
2)
3)
4)

Related product manuals