«partial stop» (N.C.) contact
- Input for EN 12978 standard-compliant safety
devices such as photocells. Gate stops if moving and
automatically shuts (if this functions has been selected).
Safety devices
RX
TX
DIR photocells
(N.C.) contact for «re-open during closing phase»
- Input for EN 12978 standard-compliant safety
devices such as photocells. If contact is opened, while
gate is closing, the gate inverts its direction.
TX
RX
DIR photocells
RX TX
./ # .#

«Partial stop» (N.C.) contact
DOC photocells
TX
./ # .#

RX
«Open while closing» (N.C.) contact
DOC photocells