DIP-SWITCH 10
1 ON - Automatic Closing - The automatic closing timer activates at the end of the opening gate run. The pre-set time is adjustable,
and is in any case conditioned by the activation of any safety devices, and does not activate after a total safety “stop” or
during a blackout.
2 ON - "Open-stop-close-stop" function with [2-7] button and radio transmitter (fi tted with inserted radiofrequency card).
2 OFF - "Open-close" function with [2-7] button and radio transmitter ((fi tted with inserted radiofrequency card).
3 ON - "Open only" function with radio transmitter ((fi tted with inserted radiofrequency card).
4 ON - Maintained action - The gate works by keeping button pressed (one 2-3P opening button , and one 2-7 closing button).
5 ON - Pre-Opening and closing fl asher - Following and opening and closing command, the fl asher connected to [W-E1], ashes
for 5 seconds before motion begins.
6 ON - Obstacle detected - When motor is stopped (gate closed or after a total stop command) it prevents any movement if safety
devices, such as photocells, detect any obstacles.
7 OFF - Opening during closing - If the photocells detect an obstacle during gates closing, gate motion is inver ted until fully opened ;
connect the safety device to terminals [2-C1]; if unused, set DIP switch to ON.
8 OFF - Partial stop - Gate stop when obstacle is detected by the safety device; once obstacle is removed, the gate remains still or
closes if automatic closing is activated. Connect the safety device to terminal [2-C3]; if unused, set the DIP switch to ON.
9 OFF - Total stop - This function stops the gate and then excludes any automatic closing cycle; to set in motion again, use either
the keypad or transmitter. Insert the safety device in [1-2]; If unused, set DIP switch to ON.
10 OFF Limit switch slowing activated
DIP-SWITCH 4
1 ON - Closing only – with command device connected on contact 2-7 (1 OFF – deactivated)
1 OFF - Open-close – with command device connected on 2-7 (see 10-way Dip Switch 2 of the function selector) (1 ON – deactivated).
2 ON - Only opening – with command device connected on contact 2-3P (2 OFF – deactivated).
2 OFF - Partial opening – with command device connected on contact 2-3P (2 ON – deactivated).
3 ON - Optical reader deactivated; (3 OFF –activated); to program deceleration you need to activated the optical reader.
4 ON - disconnected
NOTE: make selections when motor is stopped and in the closed position.
ON
OFF
/.

6.4 Function selector (dip-switch)
DIP-SWITCH 10
•• ••••••
••
AF
1234
ON
5678
910
1234
ON
DIP-SWITCH 4
/.

ON
OFF
Trimmer A.C.T. =Sets the waiting time while open. Once this time has elapsed, closing automatically takes place. The waiting time
may be set from 1 to 120 seconds.
Trimmer PAR.OP. = Sets the gate’s partial opening. By pushing the partial opening button connected at 2-3P, the gate will open for
a set time between 0 and 16 seconds.
6.5 Settings
!#4
0!2/0
•••
••
••
AF
1234
ON
5678
910
1234
ON
Pag.
14
14 - Manual code:
119BU56
119 B U 56 ver.
1.0
1.0 01/2008 © CAME cancelli automatici s.p.a. - The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s.p.a. to notify users.