6.3 Electrical connections
Terminals for powering the following accessories:
- 24V A.C. Maximum allowed power: 35W
Power supply for accessories
+
-
COM
NC
NC
COM
Gearmotor, endstop and encoder
Modifications to the electrical connections for right-hand installations
Orange
Orange
Red
White
Black
Red
Orange
Orange
Red
White
Black
Red
COM
NC
NC
COM
Description of the standard electrical connections for left-hand installations
COM
COM
Condenser
Condenser
Closing microswitch
Invert the gearmotor (U-V) and (FA-FC) endstop phases.
Opening microswitch
230V (a.c.) Power, 50/60Hz
frequency
Cable lug with bolt and washer for connecting to earth.
Pag.
11
11 -
Manual code
:
119BU56
119 B U 56
ver.
1.0
1.0 01/2008 © CAME cancelli automatici s.p.a. -
The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s.p.a. to notify users.