CAME BXV Series Specifications

General IconGeneral
EncoderYes
Power Supply230V AC, 50Hz
Max Door Weight800kg
Duty Cycle30%
Lifting Capacity800kg
Power Consumption370W
Remote ControlYes
Battery BackupOptional

Summary

INSTALLATION MANUAL

GENERAL PRECAUTIONS FOR INSTALLERS

Important safety instructions

Crucial safety guidelines for proper installation to prevent harm.

Main points of danger for people

Highlights key safety risks and entrapment points to avoid during operation.

PRODUCT DATA AND INFORMATION

Dimensions

Technical data

INSTALLATION

Preliminary operations

Steps to prepare the site, including digging holes and setting up tubes.

Laying the anchoring plate

Instructions for correctly positioning and securing the anchoring plate.

Fastening the rack

Details on how to attach the rack to the gate and secure the operator.

Foundation frame preparation

Steps for casting cement and removing the foundation frame after drying.

Setting up the operator

Guidance on placing the operator onto the anchoring plate and managing cables.

Fastening the rack to the gate

Procedures for welding or fastening the rack modules securely to the gate.

Adjusting pinion-rack coupling

Steps to ensure the correct distance between the pinion and rack for smooth operation.

Fastening the operator to the plate

Securing the operator to the anchoring plate using washers and nuts.

Mechanical limit-switch setup

Installing and adjusting limit switches for opening and closing positions.

Magnetic limit-switch setup

Configuring magnetic limit switches for gate opening and closing detection.

ELECTRICAL WIRING

Electric cables passage

Guidelines for routing electrical cables safely and in compliance with regulations.

Input voltage and connection

Instructions for connecting the operator to the power grid and managing input voltage.

Command and control devices

Connecting input devices like stop buttons, control devices, card readers, and keypads.

Safety devices connection

Connecting photocells and safety edges to ensure safe operation.

PROGRAMMING

Function of programming buttons

Explains the ESC, <>, and ENTER buttons for menu navigation and confirmation.

Safety devices test

How to activate F5 to check the operation of connected safety devices.

Obstruction handling

Configures F9 for gate behavior when an obstacle is detected.

Travel calibration

Initiates A3 for the gate's travel self-learning process.

Getting started

FINAL OPERATIONS

Error messages

Lists and explains various error codes (E1-E18) encountered during operation.