Technical data
MODELS BXV04AGS BXV06AGS BXV08AGS BXV10AGS BXV04RGS BXV06RGS BXV08RGS BXV10RGS
Power supply (V - 50/60 Hz) 230 AC 230 AC 230 AC 230 AC 110 AC 110 AC 110 AC 110 AC
Motor power supply (V) 24 DC 24 DC 24 DC 24 DC 24 DC 24 DC 24 DC 24 DC
Stand-by consumption (W) 5,5 5.5 5.5 5.5 5.5 5.5 5.5 5.5
Power (W) 170 270 400 400 170 270 400 400
Maximum current consumption (A) 7 11 16 16 7 11 16 16
Color RAL 7024 RAL 7024 RAL 7024 RAL 7024 RAL 7024 RAL 7024 RAL 7024 RAL 7024
Working temperature (°C) -20 ÷ +55 -20 ÷ +55 -20 ÷ +55 -20 ÷ +55 -20 ÷ +55 -20 ÷ +55 -20 ÷ +55 -20 ÷ +55
Thrust (N) 350 600 800 1000 350 600 800 1000
Maneuvering speed (m/min) 12 12 11 11 12 12 11 11
Work time (s) 180 180 180 180 180 180 180 180
Duty cycle HEAVY-DUTY
SERVICE
HEAVY-DUTY
SERVICE
HEAVY-DUTY
SERVICE
HEAVY-DUTY
SERVICE
HEAVY-DUTY
SERVICE
HEAVY-DUTY
SERVICE
HEAVY-DUTY
SERVICE
HEAVY-DUTY
SERVICE
Protection rating (IP) 44 44 44 44 44 44 44 44
Insulation class I I I I I I I I
MODELS BXV06AGM BXV10AGM BXV04ALS BXV06ALS BXV08ALS BXV10ALS
Power supply (V - 50/60 Hz) 230 AC 230 AC 230 AC 230 AC 230 AC 230 AC
Motor power supply (V) 24 DC 24 DC 24 DC 24 DC 24 DC 24 DC
Stand-by consumption (W) 5.5 5.5 5,5 5.5 5.5 5.5
Power (W) 270 400 170 270 400 400
Maximum current consumption (A) 11 16 7 11 16 16
Color RAL 7024 RAL 7024 RAL 7040 RAL 7040 RAL 7040 RAL 7040
Working temperature (°C) -20 ÷ +55 -20 ÷ +55 -20 ÷ +55 -20 ÷ +55 -20 ÷ +55 -20 ÷ +55
Thrust (N) 600 1000 350 600 800 1000
Maneuvering speed (m/min) 12 11 12 12 11 11
Work time (s) 180 180 180 180 180 180
Duty cycle HEAVY-DUTY
SERVICE
HEAVY-DUTY
SERVICE
HEAVY-DUTY
SERVICE
HEAVY-DUTY
SERVICE
HEAVY-DUTY
SERVICE
HEAVY-DUTY
SERVICE
Protection rating (IP) 44 44 44 44 44 44
Insulation class I I I I I I
Fuse table
MODELS BXV04AGS BXV06AGS BXV08AGS BXV10AGS BXV04RGS BXV06RGS BXV08RGS BXV10RGS
Line fuse 1.6 A-F 1.6 A-F 1.6 A-F 1.6 A-F 3.15 A-F 3.15 A-F 3.15 A-F 3.15 A-F
Accessories fuse 2 A-F 2 A-F 2 A-F 2 A-F 2 A-F 2 A-F 2 A-F 2 A-F
MODELS BXV06AGM BXV10AGM BXV04ALS BXV06ALS BXV08ALS BXV10ALS
Line fuse 1.6 A-F 1.6 A-F 1.6 A-F 1.6 A-F 1.6 A-F 1.6 A-F
Accessories fuse 2 A-F 2 A-F 2 A-F 2 A-F 2 A-F 2 A-F