p. 26 - Manual FA01442-EN - 12/2019 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Original instructions
RIO PH T1
Associate one of the available functions to a wireless safety device.
The function only appears if there is an interface board for wireless devices.
F67 RIO PH T1 OFF (Default).
P1 = Reopen while closing.
P2 = Reclose while opening.
P3 = Partial stop.
P4 = Obstacle standby.
RIO PH T2
Associate one of the available functions to a wireless safety device.
The function only appears if there is an interface board for wireless devices.
F68 RIO PH T2 OFF (Default).
P1 = Reopen while closing.
P2 = Reclose while opening.
P3 = Partial stop.
P4 = Obstacle standby.
Partial opening time
Adjust the gate opening time.
F71 Partial opening time From 5 to 40 seconds (default: 5 seconds)
New user
Register up to a maximum of 250 users and assign a function to each one.
The operation can be carried out by using a transmitter or another control device. The boards that manage the control devices (AF - R700 - R800) must
be inserted into the connectors.
Download the LIST OF REGISTERED USERS form from the docs.came.com portal by typing in L20180423.
U1 New user 1 = Step-by-step
2 = Sequential
3 = Open
4 = Partial opening
Choose the function to be assigned to the user.
Press ENTER to confirm.
Send the code from the control device.
Repeat the procedure to add other users.
Remove user
Remove one of the registered users.
U2 Remove user OFF
ON
Use the arrows to choose the number associated with the user you want to remove.
No.: 1 > 250
Alternatively, the control device associated with the user you want to remove can be
activated.
Press ENTER to confirm.
“CLr” will appear to confirm deletion.