p. 17 - Manual FA01116 -EN - 01/2018 - © CAME S.p.A. - Translated original instructions
FUNCTIONS
TRIMMER
Trimmer Description of functions
SENS
Sensibility
It adjusts the obstruction detection sensitivity during gate movement.
Minimum sensitivity (-) or maximum sensitivity (+).
A.C.T.
Automatic Closing Time
It adjusts the barrier's waiting time when it is open. Once this time elapses, the shutter automatically closes.
The waiting time may be adjusted to between 1 and 120 seconds
DIP-SWITCH Description of functions
1 ON AUTOMATIC CLOSING; set 1 to OFF to deactivate it
2 ON ONLY OPEN from button 2-7 and/or from transmitter (with AF card fitted)
2 OFF OPEN-CLOSE-INVERT from the button on 2-7 and/or from a transmitter (with AF card fitted)
3 ON 24 V output on 10-E during the boom's movement phases and when it is in closed position
3 OFF 24 V output on 10-E during the boom's movement phases
4 ON MAINTAINED ACTION; set 4 to OFF to deactivated it
5 ON PRE-FLASHING when opening and closing; the preflashing time is 5 seconds - set 5 to OFF to deactivate it.
6 ON OBSTRUCTION DETECTION when motor is idle; set 6 to OFF to deactivate it
7 ON piloted SLAVE motor; set 7 to OFF to deactivate it
8 OFF IMMEDIATE CLOSING of the boom; set 8 to ON to deactivate it
9 OFF TOTAL STOP; set 9 to ON to deactivate it
10 ON BRAKING ACTION of the boom when closing; set 10 to OFF - to deactivate it
Default settings